Local and Remote Configurationxxx | xxx61
that power device: Name, Description, Status, Version, Sockets, Vendor Name,
Model, and Input Feeds.
If a target device is connected to a power control device outlet, you can turn on,
turn off or cycle (turn off, then turn on) the target device.
To turn on, turn off or power cycle a target device:
1 From the side navigation bar, click Ports - Power Devices to open the
Power Devices screen.
2 Click the name of the unit you wish to configure and select Outlet List.
3 Select the checkbox to the left of the outlet(s) that you wish to configure.
4 Click On, Off, or Cycle, as desired.
To delete offline power devices:
1 From the side navigation bar, click Ports - Power Devices to open the
Power Devices screen.
2 Click Delete Offline.
To change the minimum on time, off time or wake up state:
1 From the side navigation bar, click Ports - Power Devices to open the
Power Devices screen.
2 Click the name of the unit you wish to configure and select Outlets.
3 Click the outlet name that you wish to modify.
4 Use the drop-down windows to alter the desired settings and click Save.
Associated Target Servers and Power Outlets
In the OBWI Target List page, power control actions are selectable for a target
with linked outlets. Selecting the Ports - Power Devices tabs, and then clicking
on a device name will display the Device Settings, Device Firmware Upgrade,
and Outlet List tabs. Click the Outlet List tab to display the outlets linked with
a target device.