Back to Contents Page
16 MB
Power
AC power supply (per power supply)
450W
100-240V, 6-3A, 50/60 Hz
1876 BTU/hr maximum
Under typical line conditions and over the entire
system ambient operating range, the inrush current
mayreach40Aperpowersupplyfor5msorlessand
60Aperpowersupplyfor1msorless.
CR 2032 3.0-V lithium ion coin cell
Physical
4.3 cm (1.68 inches)
43.7 cm (17.2 inches)
61.0 cm (24.0 inches)
12.7 kg (28 lb)
Environmental
NOTE: For additional information about environmental measurements for specific system configurations,
see www.dell.com/environmental_datasheets.
Temperature
10°to35°C(50°to95°F)
40°to65°C(40°to149°F)
Relative humidity
8% to 85% (noncondensing) with a maximum
humidity gradation of 10% per hour
5% to 95% (noncondensing)
Maximum vibration
0.25 G at 3200 Hz for 15 min
0.5 G at 3200 Hz for 15 min
Maximum shock
One shock pulse in the positive z axis (one pulse on
each side of the system) of 41 G for up to 2 ms
Six consecutively executed shock pulses in the
positive and negative x, y, and z axes (one pulse on
each side of the system) of 71 G for up to 2 ms
Altitude
16 to 3048 m (50 to 10,000 ft)
16 to 10,600 m (50 to 35,000 ft)