Dell PowerVault 51F (8P Fibre Channel Switch) Manual de usuario Pagina 94

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 168
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 93
4-30 Guía de instalación y solución de problemas del interruptor de canal de fibra de 8 puertos Dell PowerVault 51F
interruptor:admin> switchShow
switchName: open146
switchType: 3.1
switchState: Online
switchRole: Principal
switchDomain: 1
switchId: fffc41
switchWwn: 10:00:00:60:69:00:04:64
port 0: sw Online FL-Port 1 private, 1 phantom
port 1: -- No_Module G-Port
port 2: sw No_Light G-Port
port 3: sw Online FL-Port 1 private, 1 phantom
port 4: -- No_Module
port 5: sw Online E-Port 10:00:00:60:69:00:00:12 "sw1" (upstream)
port 6: sw No_Light
port 7: sw No_Light
port 8: sw No_Light
port 9: sw Online E-Port 10:00:00:60:69:00:01:b4 "sw3" (downstream)
port 10: sw No_Light
port 11: sw No_Light
port 12: sw No_Light
port 13: sw No_Light
port 14: sw No_Light
port 15: sw No_Light
value = 16 = 0x10
Tabla 4-16. Descripciones de campos de comandos
switchShow
Campo Descripción
switchName El nombre del interruptor.
switchType El número del modelo y el nivel de revisión de la placa base. El
número del modelo es el siguiente:
1
= PowerVault 50F
2 = Reservado
3
= PowerVault 51F
switchState El estado de este interruptor: en línea, fuera de línea, pro-
bando o defectuoso.
switchRole Hay tres posibilidades para
switchRole
entre las cuales se
cuentan:
Principle (Principal) — El interruptor principal según se
define en FC-SW
Subordinate (Subordinado) — Este interruptor se activa y
es un interruptor subordinado
Disabled (Desactivado)— El interruptor se desactiva.
Vista de pagina 93
1 2 ... 89 90 91 92 93 94 95 96 97 98 99 ... 167 168

Comentarios a estos manuales