Troubleshooting: Your Array 259
Troubleshooting Array and Expansion Enclosure
Connections
1
Verify that the RAID controller module port link status LED and the
RAID controller module status LED are solid green for each port that is
connected to a cable. If the LEDs are not solid green, see "Planning: RAID
Controller Modules" on page 31.
2
Ensure that all the cables are attached correctly according to array mode
you selected.
3
Turn off the server, storage array, and expansion enclosures.
4
Reseat the RAID controller module and reconnect cables on the storage
array and the server.
5
Turn on the expansion arrays and then the storage array and wait until the
system is fully booted.
6
Turn on the server.
7
Check the link status LED. If the link status LED is not green, replace the
cables.
If the problem is not resolved, see "Getting Help" on page 265.
8
Reboot the host server.
NOTE: You must turn off the host server before resetting the cables on
the storage array or expansion enclosure.
If the problem is not resolved, see "Getting Help" on page 265.