Vista de pagina 100
Storage Management Message Reference 101
2293 The EMM has
failed.
Critical /
Failure /
Error
Cause: The failure may be caused by a loss of
power to the EMM. The EMM self test may
also have identified a failure. There could also
be a firmware problem or a multi-bit error.
Action: Replace the EMM. See the hardware
documentation for information on replacing
the EMM.
None 854
2294 A device has been
inserted.
Ok / Normal Cause: This alert is for informational purposes.
Action: None
None 752
802
852
902
952
1002
1052
1102
1152
1202
2295 A device has been
removed.
Critical /
Failure /
Error
Cause: A device has been removed and the
system is no longer functioning in optimal
condition.
Action: Replace the device.
None 754
804
854
904
954
1004
1054
1104
1154
1204
2296 An EMM has been
inserted.
Ok / Normal Cause: This alert is for informational purposes.
Action: None
None 951
2297 An EMM has been
removed.
Critical /
Failure /
Error
Cause: An EMM has been removed.
Action: Replace the EMM. See the
hardware documentation for information
on replacing the EMM.
None 954
2298 There is a bad sensor
on an enclosure.
Warning /
Non-critical
Cause: The enclosure has a bad sensor. The
enclosure sensors monitor the fan speeds,
temperature probes, etc.
Action: See the hardware documentation for
more information.
None 853
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Clear
Event
Number
SNMP
Trap
Numbers
Vista de pagina 100