Dell OpenManage Server Administrator Version 7.3 Guía de usuario Pagina 381

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 567
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 380
22
Field Replaceable Unit Group
A field replaceable unit (FRU) is a part that can be removed and replaced without having to send the system to a repair
facility. The Field Replaceable Unit Group provides information about the field replaceable units that may be present in
your system.
Field Replaceable Unit Group Tables
The objects in the FRU group define information such as manufacturer, serial number, part number and revision for field
replaceable units. The following MIB tables define the FRU group.
Table 1349. Field Replaceable Unit Table
Name
fruTable
Object ID 1.3.6.1.4.1.674.10892.1.2000.10
Description Defines the Field Replaceable Unit table.
Syntax SEQUENCE OF FruTableEntry
Access Not accessible
Table 1350. FRU Table Entry
Name
fruTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1
Description Defines the FRU Table Entry.
Syntax FruTableEntry
Access Not accessible
Index
fruChassisIndex
,
fruIndex
Table 1351. FRU Chassis Index
Name
fruChassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.1
Description Defines the index (one-based) of the chassis containing the FRU.
Syntax DellObjectRange
Access Read-only
381
Vista de pagina 380
1 2 ... 376 377 378 379 380 381 382 383 384 385 386 ... 566 567

Comentarios a estos manuales

Sin comentarios