10 PowerConnect B-DCX-4S Chassis Replacement Procedure
53-1001800-01
6. Replace the port blades or filler panels (see the DCX-4S Port, Application, and Encryption Blade Replacement
Procedure and see the DCX-4S Blade Filler Panel Replacement Procedure).
7. Replace the cable management fingers (see the DCX-4S Vertical Cable Management Fingers Replacement
Procedure).
8. Connect the power cords to the power supplies and the power outlets.
9. Replace the chassis door (DCX-4S Chassis Door Replacement Procedure).
10. Power-on the PowerConnect B-DCX-4S (“Powering on the PowerConnect B-DX-4S”).
The PowerConnect B-DCX-4S performs a power-on self-test (POST). The POST takes a minimum of three minutes
and is complete when LED activity returns to the standard state.
11. Verify that the PowerConnect B-DCX-4S is powered on and POST is complete (all power LED indicators on the
port, control processor, and core switch blades should be a steady green).
12. Verify that all components are functioning correctly by checking their LEDs. If the LEDs do not indicate correct
operation, try reinstalling the corresponding component.
Verifying correct operation of system
1. Log in to the PowerConnect B-DCX-4S as admin:
switch:admin> login
login: admin
password: xxxxxxxx
switch:admin>
2. Enter the slotShow command and verify that all the installed cards are detected and that their status is
operational (enabled).
switch:admin> slotShow
Slot Blade Type ID Status
---------------------------------
1 SW BLADE 55 ENABLED
2 UNKNOWN VACANT
3 CORE BLADE 52 ENABLED
4 CP BLADE 50 ENABLED
5 CP BLADE 50 ENABLED
6 CORE BLADE 52 ENABLED
7 UNKNOWN VACANT
8 SW BLADE 51 ENABLED
switch:admin>
3. Verify that the PowerConnect B-DCX-4S is functioning correctly by typing switchShow or switchStatusShow.
This switchShow command displays PowerConnect B-DCX-4S and port status information.
switch:admin> switchshow
switchName: switch
switchType: 62.1
switchState: Online
switchMode: Native
switchRole: Subordinate
switchDomain: 11