Dell Microsoft Windows Compute Cluster Server 2003 Manual de instalación Pagina 14

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 16
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 13
14 Installation Guide
9
Copy the
.inf
and
.sys
files from the NIC driver directory,
D:\RemoteInstall\Setup\English\Images\WINDOWS\$OEM$\$1\drivers\nic
to
D:\RemoteInstall\Setup\English\Images\WINDOWS\amd64
.
10
Extract the PERC 5/i drivers into the
textmode
directory. This may require running an executable
installer and then accessing the location at which the files are installed (for example,
C:\Dell\PERC5
).
NOTE: Copy the text in the SCSI section from the file txtsetup.oem (for example, DELL PERC 5 RAID Controller
Driver [Windows Server 2003 x64]) exactly into another file. Using copy and paste is highly recommended for
this. This text can change between driver revisions.
11
Edit the
ristndrd.sif
file at
D:\RemoteInstall\Setup\English\Images\WINDOWS\amd64\templates
.
a
Add a section
MassStorageDrivers
and add the text from the SCSI section mentioned above
(use copy and paste):
[MassStorageDrivers]
"DELL PERC 5 RAID Controller Driver (Windows Server 2003 x64)"="OEM"
b
Add another section
OEMBootFiles
and list each file from the text mode directory
excluding
.txt
files
[OEMBootFiles]
nodev.inf
oemsetup.inf
percsas.cat
percsas.pdb
percsas.sys
txtsetup.oem
c
Add the following line to the
Unattended
section
OemPnpDriversPath="\Drivers\Nic"
d
Save and close the file.
12
Restart the RIS by opening a command prompt and typing
net stop binlsvc
and
net start binlsvc
.
Vista de pagina 13