Dell PowerEdge C6220 Guía de usuario Pagina 67

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 78
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 66
67
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X
BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm
Table 1-51. Configuration ID = 03h, SOL
Attribute ID Size Description R/W
SOL Idle
Timeout
12
Byte[1:2]: Define the inactivity timeout in
minutes, 1-based, LSByte first. This parameter
only applies to the IPMI over LAN session with
SOL payload activated.
0h: Session does not timeout and close due to
inactivity. Default value is 01h.
R/W
Telnet/SSH
Redirect Enable
21
•0h: Disable
•1h: SOL Enabled
•2h: SMASH Enabled
Others: Reserved
R/W
Table 1-52. Configuration ID = 04h, Security
Attribute ID Size Description R/W
Service Disabled 1 1 Disable or enable services. This attribute takes
precedence over the individual feature
enabled/disabled. Once one service has been
disabled, the BMC will not allow user to enable
the corresponding feature and D5h completion
code must be returned. For example, if
HTTP/HTTPS is disabled, user must not allow
enabling the Web Server through Web Server
Configuration (Configuration ID 0Ch). In other
words, Web can only be disabled or enabled when
HTTP/HTTPS is enabled. Default value is 38h.
[0] - All service except IPMI are disabled. This
bit takes precedence over other bits. Default is 0.
[1] - KVM/Virtual Storage, enabled by default.
•[2] - HTTP/HTTPS, enabled by default.
[3] - SSH, disabled by default.
[4] - SNMP v2c agent, disabled by default.
[5] - Telnet, disabled by default.
[6] - SMASH, disabled by default.
R/W