Dell OpenManage Server Administrator Managed Node for Fluid Cache for DAS Guía de usuario Pagina 161

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 292
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 160
Storage Management Message Reference 161
2245 A virtual disk
blink has
ceased.
OK / Normal /
Informational
Cause: This alert is for
informational purposes.
Action: None
Clear Alert:
None
Related
Alert: None
LRA
Number:
None
1201
2246 The controller
battery is
degraded.
Warning /
Non-critical
Cause: The
temperature of the the
battery is high. This
maybe due to the
battery being charged.
Action: As the charge
weakens, the charger
should automatically
recharge the battery.
If the battery has
reached its recharge
limit, replace the
battery pack. Monitor
the battery to make sure
that it recharges
successfully.
Clear Alert:
None
Related
Alert: None
LRA
Number:
2100
1153
2247 The controller
battery is
charging.
OK / Normal /
Informational
Cause: This alert is for
informational purposes.
Action: None
Clear Alert
Number:
2358
Related
Alert: None
LRA
Number:
None
1151
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related
Alert
Information
SNMP
Trap
Numbers
Vista de pagina 160
1 2 ... 156 157 158 159 160 161 162 163 164 165 166 ... 291 292

Comentarios a estos manuales

Sin comentarios