Dell OpenManage Server Administrator Managed Node for Fluid Cache for DAS Manual de usuario Pagina 143

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 390
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 142
Controllers 143
To manage physical disk power on unconfigured drives and hot spares:
1
Select
Enabled
for the
Spin Down Unconfigured Drives
and
Spin Down
Hot Spares
options.
2
Click
Apply Changes.
To exit and cancel your changes, click
Go Back to
Previous Page
.
To manage physical disk power through the Customized Power Savings
Mode:
1
Select the
Customized Power Save Mode
option.
2
Edit the remaining parameters on the
Manage Physical Disk Power
screen. Configure the options in the
QOS
section as described below.
To manage physical disk power through the QOS option:
1
Select the
Customized Power Save Mode
option.
2
In the
Spin Down Configured Drives
drop-down menu, select
Enabled
.
3
The
Quality of Service (QOS)
option is enabled. Enter the
Start Time
and
Time Interval
to spin up.
4
Click
Apply
.
To manage the time interval for the QOS option at the virtual disk level:
1
In the
Quality Of Service (QOS)
pane, select the
Enable Quality of
Service Settings
check box.
2
Set the start time. The start time can range between 1-24 hours.
3
Click
Apply Changes
.
NOTE: The Enable Quality of Service Settings option is enabled only if the
Spin Down Configured Drives option is Enabled.
To locate this task in Storage Management:
1
Expand the
Storage
tree object to display the controller objects.
2
Select a controller object.
3
Select the
Information/Configuration
subtab.
Time Interval for
Spin Up(in Hours)
The spin up time interval for the battery learn cycle. The time
interval can range from 1-24 hours.
Property Definition
Vista de pagina 142
1 2 ... 138 139 140 141 142 143 144 145 146 147 148 ... 389 390

Comentarios a estos manuales

Sin comentarios