Upgrading to Dell/EMC CX4 Series Storage Systems
Applied Technology 9
Table 3. Cable connector types used by CX enclosures
DAE2, DAE2-ATA, CX300 through CX700 SP
Host Software Upgrades
Before performing the hardware upgrade, software updates to host software may be required for compatibility with
the new system. These updates may include PowerPath, Navisphere Host Agent, Navisphere Server Utility,
Navisphere CLI, admsnap, and others. For a listing of revisions of Navisphere software supported with each FLARE
revision, see the ―Navisphere management software requirements‖ table in the EMC Navisphere Host Agent/CLI
and Utilities Release Notes on EMC Powerlink. For recommended revisions of PowerPath and admsnap refer to E-
Lab™ Navigator on EMC Powerlink.
Special Case Upgrade Paths
Some upgrade paths require special considerations. It is important to obtain the latest version of CAP2, which
contains pre-upgrade checks for many of these situations.
CX3-10c and CX4-120 Upgrades
CX3-10c systems that use SATA for the OS drives may only be upgraded to a CX4-120 with SATA OS drives.
CX4-120 systems that use SATA for the OS drives may not be upgraded. There is NOT a procedure to swap
the SATA drives for the Fibre Channel drives that are required in the larger systems. The CAP2 CRC check will
verify the OS drive type.
Low-cost HBAs in any attached servers (for example, Emulex LP-101) that are supported by the CX3-10c and
CX4-120, but are not supported by the rest of the Dell/EMC family, must be swapped out prior to conversion.
Use E-Lab Navigator to validate the new configuration.
The version of PowerPath bundled with the CX3-10c and CX4-120 is not supported by any other models in the
Dell/EMC family. PowerPath licenses must be purchased prior to the upgrade to the new storage system.
CX3-20f to CX4 Upgrades
The CX3-20f system has six FC front-end ports per SP while the base CX4-240 has only two FC front-end ports per
SP. There cannot be a loss of port count during a conversion. Therefore, an additional FC I/O module is required on
each SP. A FC UltraFlex I/O kit, consisting of a pair of FC I/O modules, must be purchased separately from array
upgrade kit.
Special Considerations for Replication Software
Private LUNs
Private LUNs used by EMC replication software cannot be migrated using LUN migration. These include clone
private LUNs (CPLs) used by SnapView™ clones, write intent log (WIL) LUNs optionally used by
MirrorView™/Synchronous mirrors, and reserved LUNs used by SnapView snapshots, SAN Copy™ incremental
sessions, and MirrorView/Asynchronous mirrors. If CAP2 identifies these as LUNs requiring relocation, they need
to be moved elsewhere, which may involve some disruption and reconfiguration of the replication software that uses
them. CPL and WIL LUNs can be moved with no disruption to clones or synchronous mirrors. Moving LUNs from
the reserved LUN pool requires destruction of all SnapView sessions, MirrorView/Asynchronous mirrors, and SAN
Copy incremental sessions using those reserved LUNs. Full resynchronizations are required for SAN Copy
incremental sessions and MirrorView/Asynchronous mirrors. For information about migrating private LUNs, review
the specialized procedure documented in the CPG.