Dell OpenManage Server Administrator Version 6.5 Guía de usuario Pagina 199

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 776
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 198
Power Group 201
Table 9-15. Battery Reading
Variable Name:
DellBatteryReading
Data Type: Integer
NOTE:
These values are bit masks, so combination values are possible.
Possible Data Values Meaning of Data Value
predictiveFailure(1) Battery sensor detects predictive failure.
failed(2) Battery has failed.
presenceDetected(4) Battery presence is detected.
Table 9-16. Power Cap Capabilities
Variable Name:
DellPowerCapCapabilities
Data Type: Integer
NOTE:
These values are bit masks, so combination values are possible.
Possible Data Values Meaning of Data Value
none(0) No power cap capabilities are available.
enable(1) Power cap can be enabled.
disable(2) Power cap can be disabled.
Table 9-17. Power Cap Setting
Variable Name:
DellPowerCapSetting
Data Type: Integer
Possible Data Values Meaning of Data Value
disabled(0) Power cap is disabled.
enabled(1) Power cap is enabled.
book.book Page 201 Monday, March 14, 2011 3:01 PM
Vista de pagina 198
1 2 ... 194 195 196 197 198 199 200 201 202 203 204 ... 775 776

Comentarios a estos manuales

Sin comentarios