Pagina 1 - Deployment Guide

Dell PowerVault MD3660i Series Storage ArraysDeployment Guide

Pagina 2 - Notes, Cautions, and Warnings

Redundant And Non-Redundant ConfigurationsNon-redundant configurations are configurations that provide only a single data path from a host to the stor

Pagina 3 - Contents

Figure 1. Four Hosts in a Dual-Controller ConfigurationIn the following figure, up to two servers are directly attached to the RAID controller modules

Pagina 4

Figure 2. Two Hosts Connected to Two ControllersIn the following figure, up to two cluster nodes are directly attached to two RAID controller modules.

Pagina 5

Figure 3. Two Cluster Nodes Connected to Two Controllers13

Pagina 6

Network-Attached ConfigurationsYou can also cable the host servers to the RAID controller module iSCSI ports through industry-standard 10 Gbps or 1 Gb

Pagina 7 - Introduction

Figure 4. 64 Servers Connected to Two ControllersThe following figure shows up to 64 stand-alone servers attached (using multiple sessions) to a dual

Pagina 8

network allow two separate physical paths for each host, which ensures full redundancy if one of the paths fails. It is recommended you use two switch

Pagina 9 - Hardware Installation

Cabling PowerVault MD3060e Expansion EnclosuresYou can expand the capacity of your PowerVault MD3660i Series storage array by adding PowerVault MD3060

Pagina 10

15. After the PowerVault MD3060e Series expansion enclosure is configured as an expansion enclosure of the storage array, restore the data that was ba

Pagina 11

3Installing MD Storage ManagerThe PowerVault MD Series resource media contains software and drivers for both Linux and Microsoft Windows operating sys

Pagina 12

Notes, Cautions, and WarningsNOTE: A NOTE indicates important information that helps you make better use of your computer.CAUTION: A CAUTION indicates

Pagina 13

Graphical Installation (Recommended)The MD Storage Manager configures, manages, and monitors the storage array. To install the MD storage manager:1. I

Pagina 14

Silent Installation Silent Installation On WindowsTo run silent installation on a Windows system:1. Copy the custom_silent.properties file in the /win

Pagina 16

4Post Installation TasksBefore using the storage array for the first time, complete a number of initial configuration tasks in the order shown. These

Pagina 17

iSCSI Configuration WorksheetThe IPv4 Settings — Worksheet and IPv6 Settings — Worksheet helps you plan your configuration. Recording host server and

Pagina 18

Storage Array ConfigurationBefore a host iSCSI initiator and an iSCSI-based storage array can communicate, they must be configured with information su

Pagina 19 - Installing MD Storage Manager

• For redundancy in a dual controller (duplex) configuration, ensure each host network interface is configured to connect to both storage array contro

Pagina 20 - Console Installation

5Guidelines For Configuring Your Network For iSCSIThis section provides general guidelines for setting up your network environment and IP addresses fo

Pagina 21 - Silent Installation

3. Restart network services using the following command:/etc/init.d/network restartUsing A DNS ServerIf you are using static IP addressing:1. In the C

Pagina 22

NETWORKING=yes HOSTNAME=mymachine.mycompany.com2. Edit the configuration file for the connection you want to configure, either /etc/sysconfig/network-

Pagina 23 - Post Installation Tasks

ContentsNotes, Cautions, and Warnings...21 Introductio

Pagina 25 - Storage Array Configuration

6Uninstalling MD Storage ManagerUninstalling MD Storage Manager From WindowsUninstall MD Storage Manager From Microsoft Windows Operating Systems Othe

Pagina 26

Uninstalling MD Storage Manager From LinuxBy default, PowerVault MD Storage Manager is installed in the /opt/dell/mdstoragemanager directory. If anoth

Pagina 27 - Microsoft Windows Host Setup

7Appendix — Manual Configuration Of iSCSIThe following sections contain step-by-step instructions for configuring iSCSI on your storage array. However

Pagina 28 - Linux Host Setup

You can discover the storage array either automatically or manually.Automatic Storage Array Discovery1. Launch MD Storage Manager.If this is the first

Pagina 29 - Using A Static IP Address

Task Purposedegrades or fails, or an adverse environmental condition occurs.Configure a storage array To create virtual disks and map them to hosts.St

Pagina 30

3. Under Target Portals, click Add and enter the IP address or DNS name of the iSCSI port on the storage array.4. If the iSCSI storage array uses a cu

Pagina 31 - Microsoft Windows Server 2008

d) Save and close the /etc/iscsi/iscsid.conf file.5. From the console, restart the iSCSI service with the following command:service iscsi start6. Veri

Pagina 32

Mutual CHAPIn addition to setting up target CHAP, you can set up mutual CHAP in which both the storage array and the iSCSI initiator authenticate each

Pagina 33

CHAP Setting DescriptionCHAP If CHAP is selected and None is deselected, the storage array requires CHAP authentication before allowing access.2. To c

Pagina 34 - Setting Up The Array

Using A DHCP server...

Pagina 35

The iSCSI port you configured on the storage array during target discovery disappears.6. Under Target Portals, click Add and re-enter the IP address o

Pagina 36

3. If you are using Mutual CHAP authentication, you can set the user name and password for CHAP authentication of the target(s) by the initiator by ed

Pagina 37 - Step 4: Configure Host Access

Step 7: Connect To The Target Storage Array From The Host ServerFor Windows Server 2008 GUI Version1. Click Start → Program → Microsoft iSCSI Initiato

Pagina 38 - (Optional)

TCP_Port_Number_Of_Target_Portal * * *Login_Flags * * * * * Username PasswordAuthtype * Mapping_Countwhere– <Target_Name> is the target name as

Pagina 39

Step 8: (Optional) Set Up In-Band ManagementOut-of-band management (see Step 1: Discover the Storage Array (Out-of-band Management Only) ) is the reco

Pagina 40

8Appendix — Using Internet Storage Naming ServiceInternet Storage Naming Service (iSNS) server, supported only on Microsoft Windows iSCSI environments

Pagina 42

9Appendix — Load BalancingWindows Load Balance PolicyMulti-path drivers select the I/O path to a virtual disk through a specific RAID controller modul

Pagina 43 - For Linux Server

The Computer Management window is displayed.2. Click Device Manager to show the list of devices attached to the host.3. Right-click the multi-path dis

Pagina 44

Figure 6. Initiator ConfigurationTwo sessions with one TCP connection are configured from the host to each controller (one session per port), for a to

Pagina 45

For Windows Server 2008 GUI Version...42For W

Pagina 47 - Appendix — Load Balancing

10Appendix — Stopping And Starting iSCSI Services In LinuxTo manually stop the iSCSI services in Linux, certain steps must be followed to maintain par

Pagina 49

11IPv4 Settings — WorksheetNOTE: If you need additional space for more than one host server, use an additional sheet.Static IP address (host server) S

Pagina 50

Static IP address (host server) Subnet Default gatewayiSCSI port 1, In 0 ___ . ___ . ___ . ___ ___ . ___ . ___ . ___ ___ . ___ . ___ . ___iSCSI port 1

Pagina 51 - Services In Linux

12IPv6 Settings — WorksheetNOTE: If you need additional space for more than one host server, use an additional sheet.Host iSCSI port 1Host iSCSI port

Pagina 52

Router IP address ____ : ____ : ____ : ____ : ____ : ____ : ____ : ____iSCSI controller 0, In 1IP address FE80 : 0000 : 0000 : 0000 : ____ : ____ : __

Pagina 54

1IntroductionThis guide provides information about deploying Dell PowerVault MD3660i storage arrays. The deployment process includes:• Hardware instal

Pagina 55 - IPv6 Settings — Worksheet

One or more host servers attached to the storage array can access the data on the storage array. You can also establish multiple physical paths betwee

Pagina 56

2Hardware InstallationBefore using this guide, ensure that you review the instructions in the:•Getting Started Guide—The Getting Started Guide that sh