Dell SE500W Guía de instalación Pagina 20

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 20
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 19
B2BIT Cluster Solution (CentOS Linux)
Page 20 of 20
November 13, 2008
Appendix A-3. Dell 1850 PowerEdge BMC controller
configuration.
1) Power on Cluster Node
2) During boot press <Ctrl+E> immediately after you see message:
Press <Ctrl><E> to enter BMC configuration setup
3) Configuration parameters for Cluster Node 1:
Main menu
IPMI over LAN: ON
IPMI LAN menu
IP address source: STATIC
Ethernet IP address: 10.0.0.3
Subnet mask: 255.255.255.248
Default gateway: 10.0.0.1
VLan enable: off
“User configuration” menu
Administrator Account: Enabled
Admin account: toor_a
Password: enter any secured password, it will be used in fence device configuration
“Host name” menu
Host name string: node-a-ipmi
Configuration parameters for Cluster Node 2:
Main menu
IPMI over LAN: ON
IPMI LAN menu
IP address source: STATIC
Ethernet IP address: 10.0.0.4
Subnet mask: 255.255.255.248
Default gateway: 10.0.0.1
VLan enable: off
“User configuration” menu
Administrator Account: Enabled
Admin account: toor_b
Password: enter any secured password, it will be used in fence device configuration
“Host name” menu
Host name string: node-b-ipmi
4) When configuration is done press “ESC” and confirm configuration saving. Press
“CTRL+ALT+DEL” after exiting from BMC configuration setup it enables a new configuration
parameters for IPMILan interface.