Dell OpenManage Server Administrator Version 5.0 Manual de usuario Pagina 105

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 248
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 104
omconfig: Managing Components Using the Instrumentation Service 105
Default Minimum and Maximum Warning Thresholds
NOTE: The capabilities for managing sensors vary by systems.
If you want to set both the upper and lower temperature warning threshold values to the recommended
default value, type:
omconfig chassis temps index=0 warnthresh=default
You cannot default one value and set another. In other words, if you default the minimum warning
threshold value, you are also selecting the default value for the maximum warning threshold value.
Specify a Value for Minimum and Maximum Warning Thresholds
NOTE: In PowerEdge x8xx and x9xx systems, warning threshold for the temperature probe can be set only for the
ambient temperature.
If you prefer to specify values for the temperature probe warning thresholds, you must specify the
number of the probe you are configuring and the minimum and/or maximum warning threshold value.
In the following example, the probe that is being configured is probe 4:
omconfig chassis temps index=4 minwarnthresh=11.2 maxwarnthresh=58.7
When you issue the command and the system sets the values you specify, the following message appears:
Temperature probe warning threshold(s) set successfully.
omconfig chassis volts
Use the omconfig chassis volts command to set voltage probe warning thresholds. As with other
components, you can view both warning and failure threshold values, but you cannot set failure
thresholds. Your system's manufacturer sets the minimum and maximum failure thresholds.
Valid Parameters for Voltage Warning Thresholds
Table 5-15 shows the valid parameters for setting voltage warning thresholds.
NOTE: Settable thresholds vary from one system configuration to another.
Table 5-15. omconfig chassis volts
name=value pair Description
index=<n> Probe index (must be specified).
warnthresh=default Sets minimum and maximum warning thresholds to default.
minwarnthresh=<n> Minimum warning threshold (3 decimal places).
maxwarnthresh=<n> Maximum warning threshold (3 decimal places).
Vista de pagina 104