64 vFoglight
Web Component Tutorial
The Query Results dialog appears, showing a list of alarms.
7
Close the Query Results dialog.
8
Click Save to save the query.
Configuring a Table of Alarms
In this exercise you are going to build a generic table that lists alarms. When the table is
actualized, the data in the table will depend on which host was chosen from the parent
dashboard. Choosing a particular host in the parent dashboard is the action that triggers
the display of the alarm table.
To add a column of aggregate alarms to a table of hosts:
1
Choose Configuration > Definitions under Dashboards in the Navigation pane
and ensure that your tutorial module (My Definitions) is selected. Also ensure
that the Views tab is selected in the Module List pane. Add a Row-Oriented Table.
For more information, see “Configuring a Row-Oriented Table” on page 40. Fill
in the properties in the General tab.
2
In the Name field, type Alarm Table for Host T3.
3
Leave Custom Purpose(s), Relevant Role(s) and Allowed Role(s) untouched.
See the Administration Guide for a discussion of these items.
4
Enter “A table of alarms for a selected host.” in both the Comments and the
Context Help text fields.
5
In the Purpose field click the Edit button, select Pagelet, and then click Apply.
The table isn’t fully configured yet, so if you try and save it now you will get an error
that informs you that column values have not been set. The next procedure shows you
how to choose columns for the table. The data in the columns’ cells will be dynamically
generated and will depend on the host.