Dell PowerVault DX6104 Manual de usuario

Busca en linea o descarga Manual de usuario para Hardware De La Computadora Dell PowerVault DX6104. Dell PowerVault DX6104 User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 6
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
02 - 2013
Statement of Volatility – Dell DX6104-CSN and
DX6104-SN
Dell DX6104-CSN and DX6104-SN systems contain both volatile and non-volatile (NV) components. Volatile
components lose their data immediately upon removal of power from the component. Non-volatile components
continue to retain their data even after the power has been removed from the component. Components chosen
as user-definable configuration options (those not soldered to the motherboard) are not included in the Statement
of Volatility. Configuration option information (pertinent to options such as microprocessors, remote access
controllers, and storage controllers) is available by component separately. The following NV components are
present in the DX6104-CSN and DX6104-SN systems.
Item Non
Volatileor
Volatile
Quantity ReferenceDesignator Size
Planer
PCHInternalCMOSRAM Non
Volatile
1 U39 256Bytes
BIOSSPIFlash Non
Volatile
1 U41 8MB
iDRACSPIFlash Non
Volatile
1 U221 4MB
BMCEMMC Non
Volatile
1 U45 2GB
SystemCPLDRAM Volatile 1 U19 8kb
SystemMemory Volatile Upto6 per
CPU
CPU1:DIMM1~DIMM6,
CPU2:DIMM7~DIMM12
Upto32GBper
DIMM
PowerSupplies
PSUFW Non
Volatile
1perPSU Variesbypartnumber Upto2MB.
Variesbypart
number
4x3.5"Backplane
SEPinternalflash Non
Volatile
1 U_SEP
Flash:32KB+
4KB
EEPROM:1KB
Vista de pagina 0
1 2 3 4 5 6

Indice de contenidos

Pagina 1 - DX6104-SN

02 - 2013 Statement of Volatility – Dell DX6104-CSN and DX6104-SN Dell DX6104-CSN and DX6104-SN systems contain both volatile and non-volatile (NV) c

Pagina 2

8x2.5"BackplaneSEPinternalflash Non‐Volatile1 U3(SEP) Flash:32KB+4KBEEPROM:1KBItem Type(e.g.FlashPROM,EEPROM)Canuserprogram

Pagina 3

andfaultbehaviors4x3.5"BackplaneSEPinternalflash IntegratedFlash+EEPROMNo Firmware+FRU8x2.5"BackplaneSEPinternalflash In

Pagina 4

Item How is this memory write protected? How is the memory cleared? Planer PCH Internal CMOS RAM N/A – BIOS only control 1) Set NVRAM_CLR ju

Pagina 5

2x2.5" Backplane SEP internal flash Program write protect bit Not user clearable 24x2.5" Backplane Flash memory Hardware str

Pagina 6 - © 2013 Dell Inc

ONFI Backup Flash Not WP. Not visible to Host Processor Flash can be cleared by powering up the card and allowing the controller to flush the content

Comentarios a estos manuales

Sin comentarios