204 Configuration: Device Mapper Multipath for Linux
Limitations and Known Issues
In certain error conditions with the no_path_retry or the
queue_if_no_path feature is set, applications may hang. To overcome
these conditions, enter the following command for each affected
multipath device:
dmsetup message [device] 0 "fail_if_no_path"
where
[device]
is the multipath device name (for example, mpath2;
do not specify the path)
I/O may hang when a Device Mapper device is deleted before the volume
is unmounted.
If the scsi_dh_rdac module is not included in initrd, slower device
discovery may be seen and the syslog may become populated with buffer
I/O error messages.
I/O may hang if the host server or storage array is rebooted while I/O is
active. All I/O to the storage array must be stopped before shutting down
or rebooting the host server or storage array.
After a failed path is restored on an MD3600i Series array, failback does not
occur automatically because the driver cannot auto-detect devices without
a forced rescan. Run the command
rescan_dm_devs
to force a rescan
of the host server. This restores the failed paths enabling failback to occur.
rescan_dm_devs Dell provided script. Forces a rescan of the host SCSI bus
and aggregates multipathing devices as needed. For use
when:
LUNs are dynamically mapped to the hosts.
New targets are added to the host.
Failback of the storage array is required.
For MD3600i Series arrays, iSCSI sessions have to be
established for rescan to take effect.
Table 14-1. Useful Device Mapper Commands
(continued)
Command Description