1)
ENUMERATE the DCIM_NICView class and note the PCID, then look up in PCID table
http://pciids.sourceforge.net/pci.ids
2) ENUMERATE the DCIM_NICString class and search for attribute ChipMdl. The
CurrentValue parameter will contain the NIC card model number.
DCIM_NICString
AttributeName = ChipMdl
CurrentValue = BCM5716 C0
DefaultValue
FQDD = NIC.Embedded.2-1
InstanceID = NIC.Embedded.2-1:ChipMdl
IsReadOnly = true
MaxLength = 0
MinLength = 0
PendingValue
3.5 List of Partitionable NIC Cards for LC2
The following is a list of partitionable NICs supported by LC2.
Broadcom
57810 bNDC – JVFVR
57810 SFP+ NIC – N20KJ
57810 Base-T NIC – W1GCR
57810 Mezz – 55GHP
57800 rNDC – MT09V
QLogic
QMD8262 bNDC – D90TX
QLE8262 NIC – JHD51
QME8262 Mezz – 9Y65N
3.6 iDRAC Telnet Attribute Enables SerialRedirection
The following behavior describes a situation where setting certain iDRAC attribute(s) causes another
iDRAC attribute to automatically and simultaneously change.
Setting any of the following Telnet attributes causes the SerialRedirection attribute to become
Enabled.
Port [ InstanceID = iDRAC.Embedded.1#Telnet.1#Port ]
Enable [ InstanceID = iDRAC.Embedded.1#Telnet.1#Enable ]
Timeout [ InstanceID = iDRAC.Embedded.1#Telnet.1#Timeout ]