Vista de pagina 522
Storage Management Group 523
Power Supply Component Status
Power Supply NexusID
Power Supply Revision
Name powerSupplyComponentStatus
Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.9
Description Severity of the power supply state. This is the combined status of the power
supply and its components. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
Syntax DellStatus
Access Read-only
Name powerSupplyNexusID
Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.10
Description Durable unique ID for this power supply.
Syntax DisplayString
Access Read-only
Name powerSupplyRevision
Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.11
Description Indicates the revision number of the power supply in the enclosure.
Syntax DisplayString
Access Read-only