Dell OpenManage Server Administrator Version 5.2 Guía de usuario Pagina 583

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 636
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 582
Traps 583
Power Supply Traps
Power supply traps provide status and warning information for power supplies present in a particular chassis.
Table 25-9. Power Supply Traps
Trap ID Description Severity Cause
Power Supply Normal
1352 Power supply returned to normal
Sensor location: <
Location in
chassis
>
Chassis location: <
Name of
chassis
>
Previous state was: <
State
>
Power Supply type:
<type of
power supply>
<Additional power supply status
information>
If in configuration error state:
Configuration error type:
<type
of configuration error>
Information A power supply has been reconnected or
replaced. The sensor location, chassis
location, previous state, and additional
information about the power supply
event are provided.
Power Supply Warning
1353 Power supply detected a warning
Sensor location: <
Location in
chassis
>
Chassis location: <
Name of
chassis
>
Previous state was: <
State
>
Power Supply type:
<type of
power supply>
<Additional power supply status
information>
If in configuration error state:
Configuration error type:
<type
of configuration error>
Warning A power supply sensor has detected a
warning condition. The sensor location,
chassis location, previous state, and
additional power supply status
information are provided.