Default Maximum power consumption timestamp.
cfgServerPowerConsumptionClear (Write Only)
Description Clears the current recorded power statistics.
This object is applicable only for iDRAC.
Legal Values 1 — Clears the Power Consumption Statistics
Default None
cfgServerPowerCapWatts (Read/Write)
Description Represents the server power threshold in Watts.
This object is applicable only for iDRAC.
NOTE: This value is applicable only if
cfgServerPowerCapEnable is set to 1.
Legal Values None
Default Server power threshold in Watts.
cfgServerPowerCapBtuhr (Read/Write)
Description Represents the server power threshold in BTU/hr.
This object is applicable only for iDRAC.
NOTE: This value is applicable only if
cfgServerPowerCapEnable is set to 1.
Legal Values None
Default Server power threshold in BTU/hr.
cfgServerPowerCapPercent (Read/Write)
Description Represents the server power threshold in percentage.
This object is applicable only for iDRAC.
NOTE: This value is applicable only if
cfgServerPowerCapEnable is set to 1.
Legal Values None
Default Server power threshold in percentage.