getkvminfo
Description Displays iKVM module information.
To use this subcommand, you must have CMC Login User privilege.
Synopsis
racadm getkvminfo
Example
racadm getkvminfo
<
module
> <
presence
> <
model
> <
FW Version
> <
status
>
KVM Present Avocent iKVM
Switch
00.05.00.04 Ready
getled
Description Displays the LED settings on a module: blinking, not
blinking, or unknown (for empty slots).
To use this subcommand, you must have Login User
privilege.
Synopsis
racadm getled -m <module>
Input CMC only options:
-m <
module
> — Specifies the module whose LED settings
you want to view.
<
module
> can be one of the following:
server-nx where n=1-8; x=a,b,c,d
switch-n where n=1– 6
chassis
cmc-active
Output
Example For CMC:
racadm getled -m server-10
<
module
> <
LED state
> server-10 Blinking
racadm getled -m chassis
<
module
> <
LED state
> server-10 Not blinking
racadm getled -m server-1
<
module
> <
LED state
> server-1 ON
racadm getled -m server-9
<
module
> <
LED state
> server-9 Extension(1)
For iDRAC:
racadm getled
LED is blinking