Pagina 1 - User’s Guide

www.dell.com | support.dell.comDell™ PowerEdge™ ExpandableRAID Controller (PERC) 6/i,PERC 6/E and CERC 6/iUser’s GuideDell_PERC6.2_UG.book Page 1 We

Pagina 2 - Notes, Cautions, and Warnings

10 ContentsDell_PERC6.2_UG.book Page 10 Wednesday, June 24, 2009 6:08 PM

Pagina 3 - Contents

100 Configuring and Managing RAID NOTE: The List View of the Virtual Disk Management screen displays different options from the Tree View. Space Allo

Pagina 4 - 4 Contents

Configuring and Managing RAID 101Virtual Disk ActionsTable 6-4 describes the actions you can perform on virtual disks. For procedures you can use to p

Pagina 5

102 Configuring and Managing RAID• Performing the Replace Member operation• Setting the LED to blink• Making a disk online or offline (unaffiliated wi

Pagina 6 - 6 Contents

Configuring and Managing RAID 103RebuildSelect Rebuild to rebuild one or more failed physical disks. For information on performing a physical disk reb

Pagina 7

104 Configuring and Managing RAIDController Management ActionsTable 6-6 describes the actions you can perform on the Ctrl Mgmt screen.Foreign Configur

Pagina 8 - 8 Contents

Configuring and Managing RAID 105The section "Importing or Clearing Foreign Configurations Using the Foreign Configuration View Screen" on p

Pagina 9 - Contents 9

106 Configuring and Managing RAIDPerform the following steps to create global hot spares.1Press <Ctrl><N> to access the PD Mgmt screen.A l

Pagina 10 - 10 Contents

Configuring and Managing RAID 1074Press the down-arrow key to select Remove Hot Spare from the list of actions and press <Enter>.The physical di

Pagina 11 - WARNING: Safety Instructions

108 Configuring and Managing RAIDRestrictions and LimitationsThe following restrictions and limitations apply to the Replace Member operation:•The Rep

Pagina 12

Configuring and Managing RAID 1093Press <F2> to display a menu of available actions.The Rebuild option is highlighted at the top of the menu.4Pr

Pagina 13

WARNING: Safety Instructions 11WARNING: Safety InstructionsUse the following safety guidelines to help ensure your own personal safety and to help pro

Pagina 14 - SAFETY: Battery Disposal

110 Configuring and Managing RAIDAfter you enable the BIOS for a controller, perform the following steps to enable the boot support for that controlle

Pagina 15 - Overview

Configuring and Managing RAID 111Restoring Factory Default SettingsYou can use the Ctrl Mgmt menu screen to restore the default settings for the optio

Pagina 16 - RAID Description

112 Configuring and Managing RAIDDell_PERC6.2_UG.book Page 112 Wednesday, June 24, 2009 6:08 PM

Pagina 17 - RAID Terminology

Troubleshooting 113TroubleshootingTo get help with your Dell™ PowerEdge™ Expandable RAID Controller (PERC) 6 and Dell Cost-Effective RAID Controller (

Pagina 18 - Disk Mirroring

114 TroubleshootingAdapter at Baseport xxxx is not respondingwhere xxxx is the baseport of the controllerIf the BIOS detects the controller but the co

Pagina 19 - Parity Data

Troubleshooting 115Memory/Battery problems were detected. The adapter has recovered, but cached data was lost. Press any key to continue.This message

Pagina 20 - 20 Overview

116 TroubleshootingForeign configuration(s) found on adapter. Press any key to continue, or ’C’ to load the configuration utility or ’F’ to import for

Pagina 21 - Controllers

Troubleshooting 117Invalid SAS topology detected. Please check your cable configurations, repair the problem, and restart your system.The SAS cables f

Pagina 22

118 TroubleshootingSome configured disks have been removed from your system or are no longer accessible. Check your cables and ensure all disks are pr

Pagina 23

Troubleshooting 119Table 7-2 describes the BBU-related error messages and warnings.Virtual Disks DegradedA redundant virtual disk is in a degraded sta

Pagina 24 - Using the SMART Feature

12 WARNING: Safety Instructions• Operate the product only from the type of external power source indicated on the electrical ratings label. If you are

Pagina 25 - Initializing Virtual Disks

120 TroubleshootingMemory ErrorsMemory errors can corrupt cached data, so the controllers are designed to detect and attempt to recover from these mem

Pagina 26 - Consistency Checks

Troubleshooting 121General ProblemsTable 7-3 describes general problems you might encounter, with suggested solutions.Table 7-3. General ProblemsProbl

Pagina 27 - Disk Migration

122 TroubleshootingPhysical Disk Related IssuesTable 7-4 describes physical disk-related problems you might encounter, with suggested solutions.Table

Pagina 28

Troubleshooting 123Physical Disk Failures and RebuildsTable 7-5 describes issues related to physical disk failures and rebuilds.Table 7-5. Physical Di

Pagina 29

124 TroubleshootingRebuilding a physical disk after one of them is in a failed state.If you have configured hot spares, the PERC 6 controller automati

Pagina 30 - Battery Management

Troubleshooting 125SMART ErrorsTable 7-6 describes issues related to the Self-Monitoring Analysis and Reporting Technology (SMART). SMART monitors the

Pagina 31 - Battery Learn Cycle

126 TroubleshootingReplace Member ErrorsTable 7-7 describes issues related to the Replace Member feature. NOTE: For more information about the Repla

Pagina 32 - Write-Back and Write-Through

Troubleshooting 127Linux Operating System ErrorsTable 7-8 describes issues related to the Linux operating system.Table 7-8. Linux Operating System Err

Pagina 33 - Reconfiguring Virtual Disks

128 TroubleshootingDriver does not auto-build into new kernel after customer updates.This error is a generic problem for Dynamic Kernel Module Support

Pagina 34

Troubleshooting 129Controller LED IndicatorsThe external SAS ports on the PERC 6/E adapter have a port status LED per x4 SAS port. This bi-color LED d

Pagina 35

WARNING: Safety Instructions 13In addition, note these safety guidelines when appropriate:• When you disconnect a cable, pull on its connector or on i

Pagina 36 - Fault Tolerance Features

130 TroubleshootingDrive Carrier LED IndicatorsThe LED on the physical disk carrier indicates the state of each physical disk. Each drive carrier in y

Pagina 37

Troubleshooting 131Green/amber flashing(Green On 500 ms / Amber On 500 ms, Off 1000 ms)Predicted failure reported by driveGreen flashing(Green On 3000

Pagina 38 - Patrol Read

132 TroubleshootingDell_PERC6.2_UG.book Page 132 Wednesday, June 24, 2009 6:08 PM

Pagina 39 - Patrol Read Modes

Regulatory Notices 133Regulatory NoticesFor additional regulatory information, please go to the Regulatory Compliance Homepage on www.dell.com at the

Pagina 40

134 Regulatory NoticesDell_PERC6.2_UG.book Page 134 Wednesday, June 24, 2009 6:08 PM

Pagina 41 - Hardware

Corporate Contact Details (Taiwan Only) 135Corporate Contact Details (Taiwan Only)Pursuant to Article 11 of the Commodity Inspection Act, Dell provide

Pagina 42

136 Corporate Contact Details (Taiwan Only)Dell_PERC6.2_UG.book Page 136 Wednesday, June 24, 2009 6:08 PM

Pagina 43

Glossary 137GlossaryAAdapterAn adapter enables the computer system to access peripheral devices by converting the protocol of one bus or interface to

Pagina 44

138 GlossaryBattery Backup Unit (BBU)The battery backup unit protects the integrity of the cached data on the controller by providing backup power if

Pagina 45

Glossary 139CachingThe process of utilizing a high speed memory buffer, referred to as a “cache,” in order to speed up the overall read or write perfo

Pagina 46 - Unit (TBBU) on PERC 6/E

14 WARNING: Safety InstructionsYou can also take the following steps to prevent damage from electrostatic discharge:• When unpacking a static-sensitiv

Pagina 47

140 GlossaryDisk ArrayA collection of disks from one or more disk subsystems combined using a configuration utility. The utility controls the disks an

Pagina 48

Glossary 141DKMSAcronym for Dynamic Kernel Module Support. Designed by Dell™, DKMS creates a framework in which kernel-dependent module source can res

Pagina 49

142 GlossaryFFailed Physical DiskA physical disk that has ceased to function, that consistently functions improperly, or that is inaccessible.Fault To

Pagina 50

Glossary 143GGBAcronym for gigabyte(s). A gigabyte equals 1,024 megabytes or 1,073,741,824 bytes (2^30 bytes).HHost SystemAny system on which the RAID

Pagina 51

144 GlossaryIInitializationThe process of writing zeros to the data fields of a virtual disk and, in fault tolerant RAID levels, generating the corres

Pagina 52

Glossary 145Logical DiskA set of contiguous chunks on a physical disk. Logical disks are used in array implementations as constituents of logical volu

Pagina 53

146 GlossaryNNon Read AheadNon read ahead is a cache read policy. If you select Non read ahead in the BIOS Configuration Utility, the controller does

Pagina 54

Glossary 147Online Capacity ExpansionOperation to add capacity to an existing virtual disk by adding an additional physical disk while the host system

Pagina 55 - PERC 6/E Adapter

148 GlossaryPHYThe interface required to transmit and receive data packets transferred across the serial bus.Each PHY can form one side of the physica

Pagina 56

Glossary 149ProtocolA set of formal rules describing how to transmit data, generally across a network or when communicating with storage subsystems. L

Pagina 57

Overview 15OverviewThe Dell™ PowerEdge™ Expandable RAID Controller (PERC) 6 family of controllers and the Dell Cost-Effective RAID Controller (CERC) 6

Pagina 58

150 GlossaryThe Dell OpenManage™ storage management application configures the disks after you have installed the operating system. Storage Management

Pagina 59 - Procedure)

Glossary 151Redundant Virtual DiskA redundant virtual disk is one which has redundant data on physical disks in the disk group that can be used to reb

Pagina 60

152 GlossaryRPMAcronym for Red Hat Package Manager. RPM is a software manager used to install, remove, query, and verify the software on your system.

Pagina 61

Glossary 153SMARTAcronym for Self-Monitoring Analysis and Reporting Technology. The self-monitoring analysis and reporting technology (SMART) feature

Pagina 62

154 GlossarySSPAcronym for Serial SCSI Protocol. SSP enables communication with other SAS devices. Each PHY on the SAS controller can function as an S

Pagina 63 - Driver Installation

Glossary 155VVirtual DiskA virtual disk refers to storage created by a RAID controller from one or more physical disks. Although a virtual disk may be

Pagina 64 - Installing Windows Drivers

156 GlossaryDell_PERC6.2_UG.book Page 156 Wednesday, June 24, 2009 6:08 PM

Pagina 65 - Operating System Installation

Index 157IndexBbackground initialization, 25, 137stopping, 108baseport, 137batteryinstalling transportable battery backup, 46management, 30removing fr

Pagina 66 - Installation

158 IndexEelectrostatic discharge. See ESDESD, 13Ffault tolerance, 34features, 34foreign configuration, 104Foreign Configuration View, 104Hhot swap, 1

Pagina 67

Index 159management, 101post error messages, 113RRAID, 143-144configuration, 77configuration and management, 77configuration functions, 83configuratio

Pagina 68

16 OverviewOperating System SupportThe PERC 6 and CERC 6/i controllers support the following operating systems:• Citrix® XenServer® Dell Edition• Micr

Pagina 69 - Installing Linux Driver

160 IndexWWindows, 63drivers, 63updating drivers, 68Windows XP DriverInstallation on an Existing System, 76write policy, 84Dell_PERC6.2_UG.book Page

Pagina 70

Overview 17Summary of RAID Levels• RAID 0 uses disk striping to provide high data throughput, especially for large files in an environment that requir

Pagina 71 - Update Diskette

18 OverviewFor example, in a four-disk system using only disk striping (used in RAID 0), segment 1 is written to disk 1, segment 2 is written to disk

Pagina 72

Overview 19Figure 2-2 shows an example of disk mirroring.Figure 2-2. Example of Disk Mirroring (RAID 1)Spanned RAID LevelsSpanning is a term used to d

Pagina 73 - Upgrading the Kernel

Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your system. CAUTION: A CAUTION indicate

Pagina 74 - Installing Solaris Driver

20 OverviewFigure 2-3. Example of Distributed Parity (RAID 5) NOTE: Parity is distributed across multiple physical disks in the disk group.Figure 2-4.

Pagina 75 - Installing NetWare Drivers

About PERC 6 and CERC 6/i Controllers 21About PERC 6 and CERC 6/i ControllersThis section describes the features of the Dell™ PowerEdge™ Expandable RA

Pagina 76

22 About PERC 6 and CERC 6/i ControllersBattery Backup UnitYes, TransportableYesbYes NoCache Memory256-MB DDRII cache memory size.Optional 512-MB DIMM

Pagina 77

About PERC 6 and CERC 6/i Controllers 23Multiple Virtual Disks per ControllerUp to 64 virtual disks per controllerUp to 64 virtual disks per controlle

Pagina 78 - RAID Configuration Functions

24 About PERC 6 and CERC 6/i Controllers NOTE: The maximum array size is limited by the maximum number of drives per disk group (32), the maximum num

Pagina 79

About PERC 6 and CERC 6/i Controllers 25A SMART failure is also referred to as a predicted failure. There are numerous factors that relate to predicte

Pagina 80 - Menu Navigation Controls

26 About PERC 6 and CERC 6/i ControllersFull Initialization of Virtual DisksPerforming a Full Initialization on a virtual disk overwrites all blocks a

Pagina 81

About PERC 6 and CERC 6/i Controllers 27Disk RoamingThe PERC 6 and CERC 6/i controllers support moving physical disks from one cable connection or bac

Pagina 82

28 About PERC 6 and CERC 6/i ControllersPerform the following steps to use disk migration:1Turn off the system that contains the source controller.2Mo

Pagina 83 - Setting Up Virtual Disks

About PERC 6 and CERC 6/i Controllers 29Migrating Virtual Disks from SAS 6/iR to PERC 6 and CERC 6/i NOTE: The supported operating systems listed in

Pagina 84

Contents 3Contents1 WARNING: Safety Instructions . . . . . . . . 11SAFETY: General . . . . . . . . . . . . . . . . . . 11SAFETY: When Working Insi

Pagina 85 - Virtual Disk Management

30 About PERC 6 and CERC 6/i Controllers6Exit the BIOS Configuration Utility and reboot the system.7Ensure all the latest drivers for PERC 6 or CERC 6

Pagina 86

About PERC 6 and CERC 6/i Controllers 31Battery Learn CycleLearn cycle is a battery calibration operation performed by the controller periodically to

Pagina 87

32 About PERC 6 and CERC 6/i ControllersVirtual Disk Write Cache PoliciesThe write cache policy of a virtual disk determines how the controller handle

Pagina 88 - Checking Data Consistency

About PERC 6 and CERC 6/i Controllers 33Conditions Under Which Write-Through is EmployedWrite-Through caching is used under all conditions in which th

Pagina 89

34 About PERC 6 and CERC 6/i ControllersRAID level. When a RLM/OCE operation is complete, a reboot is not necessary. For a list of RAID level migratio

Pagina 90 - Configuration View Screen

About PERC 6 and CERC 6/i Controllers 35 NOTE: The total number of physical disks in a disk group cannot exceed 32. NOTE: You cannot perform RAID le

Pagina 91

36 About PERC 6 and CERC 6/i ControllersFault Tolerance FeaturesTable 3-3 lists the features that provide fault tolerance to prevent data loss in case

Pagina 92

About PERC 6 and CERC 6/i Controllers 37Failed Physical Disk DetectionThe controller automatically detects and rebuilds failed physical disks when you

Pagina 93 - Managing Preserved Cache

38 About PERC 6 and CERC 6/i ControllersAutomatic Replace Member with Predicted FailureA Replace Member operation can occur when there is a SMART pred

Pagina 94 - Managing Dedicated Hot Spares

About PERC 6 and CERC 6/i Controllers 393Patrol Read adjusts the amount of controller resources dedicated to Patrol Read operations based on outstandi

Pagina 95 - Deleting Disk Groups

4 ContentsInitializing Virtual Disks . . . . . . . . . . . . . . . . . 25Background Initialization. . . . . . . . . . . . . . 25Full Initializatio

Pagina 96 - Resetting the Configuration

40 About PERC 6 and CERC 6/i ControllersDell_PERC6.2_UG.book Page 40 Wednesday, June 24, 2009 6:08 PM

Pagina 97

Installing and Configuring Hardware 41Installing and Configuring Hardware WARNING: Only trained service technicians are authorized to remove the syst

Pagina 98

42 Installing and Configuring Hardware5Align the PERC 6/E adapter to the PCI-E slot you have selected. CAUTION: Never apply pressure to the adapter m

Pagina 99

Installing and Configuring Hardware 43Figure 4-2. Installing a PERC 6/i Adapter7Tighten the bracket screw, if any, or use the system’s retention clips

Pagina 100

44 Installing and Configuring Hardware9Connect the cable from the external enclosure to the controller. For more information, see Figure 4-3.Figure 4-

Pagina 101 - Virtual Disk Actions

Installing and Configuring Hardware 45Figure 4-4. Connecting Cables to the Controller11Replace the cover of the system. For more information on closin

Pagina 102

46 Installing and Configuring HardwareInstalling the Transportable Battery Backup Unit (TBBU) on PERC 6/E CAUTION: The following procedure must be pe

Pagina 103

Installing and Configuring Hardware 474Place the PERC 6/E adapter on a flat, clean, and static–free surface.5Mount the memory module in the controller

Pagina 104 - Foreign Configuration View

48 Installing and Configuring HardwareFigure 4-6. Installing a DIMMTransferring a TBBU Between ControllersThe TBBU provides uninterrupted power supply

Pagina 105 - Physical Disk Management

Installing and Configuring Hardware 49Perform the following steps to replace a failed controller with data in the TBBU:1Perform a controlled shutdown

Pagina 106 - Configuring and Managing RAID

Contents 5Redundant Path With Static LoadBalancing Support . . . . . . . . . . . . . . . . . 37Using Replace Member and RevertibleHot Spares . . . .

Pagina 107

50 Installing and Configuring Hardware3Locate the PERC 6/E adapter in the system and disconnect the external cables from the adapter. NOTE: The locat

Pagina 108 - Restrictions and Limitations

Installing and Configuring Hardware 515Determine whether the Dirty Cache LED on the controller is illuminated. For location of the LED, see Figure 4-8

Pagina 109 - Controller Management

52 Installing and Configuring HardwareRemoving the DIMM and Battery from a PERC 6/E Adapter NOTE: The TBBU on the PERC 6/E adapter consists of a DIMM

Pagina 110 - Enabling BIOS Stop on Error

Installing and Configuring Hardware 53Figure 4-9. PERC 6/E Adapter Dirty Cache LED Location5Press down on the tabs at each edge of the DIMM slot until

Pagina 111

54 Installing and Configuring HardwareFigure 4-10. Removing the TBBUDisconnecting the BBU from a PERC 6/i Adapter or a PERC 6/i Integrated Controller

Pagina 112

Installing and Configuring Hardware 551Perform a controlled shutdown on the system in which the PERC 6/i is installed.2Disconnect the system from the

Pagina 113 - Troubleshooting

56 Installing and Configuring HardwareIf the connection between an Out port on the controller and an In port on an enclosure fails, an alternate path

Pagina 114 - 114 Troubleshooting

Installing and Configuring Hardware 57Figure 4-13 displays Redundant path Storage Configuration with three enclosuresFigure 4-13. Redundant Path Suppo

Pagina 115

58 Installing and Configuring HardwarePerform the following steps to configure the hardware to utilize redundant paths on the PERC 6/E adapter:1Set up

Pagina 116 - 116 Troubleshooting

Installing and Configuring Hardware 59Removing and Installing the PERC 6/i and CERC 6/i Integrated Storage Controller Cards in Dell Modular Blade Syst

Pagina 117

6 Contents5 Driver Installation . . . . . . . . . . . . . . . . . 63Installing Windows Drivers . . . . . . . . . . . . . . . 64Creating the Drive

Pagina 118 - X. Perform a rescan after

60 Installing and Configuring HardwareFigure 4-14. Removing and Installing the Storage Controller CardInstalling the Storage Controller CardTo install

Pagina 119 - Virtual Disks Degraded

Installing and Configuring Hardware 615Close the top cover of the Modular Blade system. For more information on closing the top cover of the Modular B

Pagina 120 - Pinned Cache State

62 Installing and Configuring HardwareDell_PERC6.2_UG.book Page 62 Wednesday, June 24, 2009 6:08 PM

Pagina 121 - General Problems

Driver Installation 63Driver InstallationThe Dell™ PowerEdge™ Expandable RAID Controller (PERC) 6 and Dell Cost-Effective RAID Controller (CERC) 6/i f

Pagina 122 - Physical Disk Related Issues

64 Driver InstallationInstalling Windows DriversCreating the Driver MediaPerform the following steps to create the driver media:1Browse to the downloa

Pagina 123

Driver Installation 654From the list of drivers displayed, select the driver you require. Select the self-extracting zip file and click Run. Copy the

Pagina 124 - 124 Troubleshooting

66 Driver Installation3Press the <S> key.The system prompts for the driver media to be inserted. NOTE: The driver can be provided using a prope

Pagina 125 - SMART Errors

Driver Installation 67Installing a Windows Server 2003, Windows Server 2008, Windows Vista, or Windows XP Driver for a New RAID Controller NOTE: PERC

Pagina 126 - Replace Member Errors

68 Driver InstallationUpdating an Existing Windows Server 2003, Windows Server 2008, Windows XP, or Windows Vista Driver NOTE: Close all applications

Pagina 127 - Linux Operating System Errors

Driver Installation 6912Click Next and continue the installation steps in the Wizard.13Click Finish to exit the wizard and reboot the system for the c

Pagina 128 - 128 Troubleshooting

Contents 76 Configuring and Managing RAID. . . . . . . 77Dell OpenManage Storage Management . . . . . . . . 77Dell SAS RAID Storage Manager . . . .

Pagina 129 - Controller LED Indicators

70 Driver Installation3Use the dd command to create a driver update disk. Use the appropriate image for the purpose.dd if=<name of the dd image fil

Pagina 130 - Drive Carrier LED Indicators

Driver Installation 71Installing Red Hat Enterprise Linux Operating System Using the Driver Update DiskettePerform the following steps to install Red

Pagina 131

72 Driver Installation6Click OK.If you want to install from another driver update medium, continue with the following steps.7The system displays the m

Pagina 132 - 132 Troubleshooting

Driver Installation 73Upgrading the KernelWhen upgrading to a new kernel, you must reinstall the DKMS-enabled driver packages. Perform the following s

Pagina 133 - Regulatory Notices

74 Driver InstallationInstalling Solaris DriverUse the procedures in this section to install the driver for Solaris 10. To ensure that you have the cu

Pagina 134 - 134 Regulatory Notices

Driver Installation 755Select [3] if you created a diskette from the mega_sas.img file and you are using a removable (USB) diskette drive.6Follow inst

Pagina 135 - Tai p e i , Tai w a n

76 Driver Installation4From the screen that displays, go to the Storage Adapter screen to install the MegaRAID SAS driver.5Delete any existing RAID ad

Pagina 136

Configuring and Managing RAID 77Configuring and Managing RAIDDell™ OpenManage™ storage management applications enable you to manage and configure the

Pagina 137 - Glossary

78 Configuring and Managing RAIDRAID Configuration FunctionsAfter you attach physical disks, use a configuration utility to organize the disks into vi

Pagina 138 - BIOS Configuration Utility

Configuring and Managing RAID 79BIOS Configuration UtilityThe BIOS Configuration Utility, also known as Ctrl+R, is a storage management application em

Pagina 139 - Glossary 139

8 ContentsReplacing an Online Physical Disk . . . . . . . . 107Stopping Background Initialization. . . . . . . . 108Performing a Manual Rebuild of

Pagina 140

80 Configuring and Managing RAID NOTE: You can access multiple controllers through the BIOS Configuration Utility by pressing <F12>. NOTE: You

Pagina 141 - Glossary 141

Configuring and Managing RAID 81up-arrow keyUse the up-arrow key to move to the upper menu items within a menu or to a higher level menu. You can also

Pagina 142

82 Configuring and Managing RAID<Tab> Press <Tab> to move the cursor to the next control on a dialog box or page.Press <Tab> to move

Pagina 143 - Glossary 143

Configuring and Managing RAID 83Setting Up Virtual DisksYou can set up a disk group and create virtual disks using the procedures contained in this se

Pagina 144 - Load-balancing

84 Configuring and Managing RAIDTable 6-2 shows the parameters that you can configure when defining virtual disks.Table 6-2. Virtual Disk Parameters a

Pagina 145 - Glossary 145

Configuring and Managing RAID 85Virtual Disk Management Creating Virtual Disks NOTE: Combining SAS and SATA hard disk drives (HDDs) within a virtual

Pagina 146

86 Configuring and Managing RAID2Use the arrow keys to highlight Controller # or Disk Group #.3Press <F2> to display the actions you can perform

Pagina 147 - Glossary 147

Configuring and Managing RAID 8715Perform the following steps to select the virtual disk parameters:aPress <Tab> to move the cursor to the param

Pagina 148 - Physical Disk States

88 Configuring and Managing RAIDlIf you have chosen to create hot spares in the earlier steps, a pop-up window displays where drives with appropriate

Pagina 149 - Glossary 149

Configuring and Managing RAID 89If you attempt to run a Consistency Check on a virtual disk that has not been initialized, the following error message

Pagina 150 - Redundancy

Contents 9A Regulatory Notices . . . . . . . . . . . . . . . . 133B Corporate Contact Details (Taiwan Only) 135Glossary. . . . . . . . . . . . . . .

Pagina 151 - Revertible Hot Spare

90 Configuring and Managing RAIDPerform the following steps to import or clear foreign configurations.1During bootup, press <Ctrl><R> when

Pagina 152

Configuring and Managing RAID 91You can use the Foreign Configuration View screen to manage foreign configurations in the following cases:• All the ph

Pagina 153 - Spanning

92 Configuring and Managing RAID NOTE: When you import a foreign configuration, the dedicated hot spares in the configuration are imported as dedicat

Pagina 154

Configuring and Managing RAID 93Managing Preserved CacheIf a virtual disk becomes offline or is deleted because of missing physical disks, the control

Pagina 155 - Write-Through

94 Configuring and Managing RAIDManaging Dedicated Hot SparesA dedicated hot spare automatically replaces a failed physical disk only in the selected

Pagina 156 - 156 Glossary

Configuring and Managing RAID 954Press <Enter> to confirm the changes.The VD Mgmt screen displays the updated list of hot spares under the Hot s

Pagina 157 - Index 157

96 Configuring and Managing RAID3Press <F2>.The action menu displays.4Select Delete Disk Group and press <Enter>.The disk group is deleted

Pagina 158

Configuring and Managing RAID 97•Controller Management (Ctrl Mgmt) menu•Foreign Configuration View menuMost menus consist of two panels:• A left panel

Pagina 159 - Index 159

98 Configuring and Managing RAIDTable 6-3. Information on the Virtual Disk Management ScreenMenu Item Selected in Left PanelInformation Displayed in R

Pagina 160

Configuring and Managing RAID 99Physical Disks Disk Group # Properties:• Number of virtuals disks (VD)• Number of physical disks (PD)• Space available