Installing and Configuring Hardware 51
5
Determine whether the Dirty Cache LED on the controller is illuminated.
For location of the LED, see Figure 4-8
If the LED is illuminated, replace the system cover, reconnect the
system to power, turn on the system, and repeat step 1 and step 2.
If the LED is not illuminated, continue with the next step.
6
Disconnect the data cables and battery cable from the PERC 6/i.
Remove any retention mechanism, such as a bracket screw, that might be
holding the PERC 6/i in the system, and gently lift the controller from the
system’s PCI-E slot.
Figure 4-8. Removing the PERC 6/i Adapter
1 bracket screw 3 dirty cache LED
2 PERC 6/i controller
2
3
1
Dell_PERC6.2_UG.book Page 51 Wednesday, June 24, 2009 6:08 PM