250 Virtual Disks
Before continuing with the virtual disk reconfiguration, you should be
familiar with the information in Starting and Target RAID Levels for Virtual
Disk Reconfiguration and Capacity Expansion and Choosing RAID Levels
and Concatenation.
NOTE: You cannot reconfigure a virtual disk on a controller that is operating in
cluster mode.
NOTE: You can create no more than 64 virtual disks on a controller. After you have
reached this limit, you can no longer reconfigure any of the virtual disks on the
controller. But, for IR and PERC H200 controllers, you can create only two virtual
disks
.
NOTE: On Linux, if you do a reconfigure on the same controller on which the
operating system resides, you may experience extremely slow system performance
until the reconfigure is complete.
NOTE: You may want to review Virtual Disk Considerations for Controllers. This
section contains considerations that also apply to reconfiguring a virtual disk on
these controllers.
To Reconfigure a Virtual Disk: Step 1 of 3
1
Select the physical disks that you want to include in the virtual disk. You
can expand the virtual disk’s capacity by adding additional physical disks.
On some controllers, you can also remove physical disks.
The changes you make to the physical disk selection are displayed in the
Selected Physical Disks
table.
NOTE: For a controller that has more than one channel, it may be possible to
configure a virtual disk that is channel-redundant. For more information, see
Channel Redundancy and Thermal Shutdown.
NOTE: For PERC H310 Adapter, PERC H310 Mini Monolithic, PERC H310 Mini
Blades, PERC H700, PERC H710 Adapter, PERC H710 Mini Blades, PERC H710 Mini
Monolithic, PERC H710P Adapter, PERC H710P Mini Blades, PERC H710P Mini
Monolithic, PERC H800, and PERC H810 Adapter controllers
,
if any of the selected
physical drives is in the spun down state, the system displays a message that
indicates the IDs of the spun down drives and the delay in executing tasks on them.
NOTE: For PERC H310 Adapter, PERC H310 Mini Monolithic, PERC H310 Mini
Blades, PERC H700, PERC H710 Adapter, PERC H710 Mini Blades, PERC H710 Mini
Monolithic, PERC H710P Adapter, PERC H710P Mini Blades, PERC H710P Mini