omconfig storage Commands 217
where id is the controller ID. The <PDISK> variable specifies the
physical disk.
To obtain these values, type omreport storage controller to display the
controller IDs and then type omreport storage pdisk controller=ID to
display the IDs for the physical disks attached to the controller.
Example Syntax
In this example, you want to assign physical disk 3 on connector 0 of
controller 1 as a global hot spare. On a SAS controller, the physical disk
resides in enclosure 2.
Example for SCSI, SATA, and ATA Controllers
To assign the physical disk described in this example as a global hot spare,
type:
omconfig storage pdisk action=assignglobalhotspare
controller=1 pdisk=0:3 assign=yes
Example for SAS Controllers
To assign the physical disk described in this example as a global hot spare,
type:
omconfig storage pdisk action=assignglobalhotspare
controller=1 pdisk=0:2:3 assign=yes
omconfig Rebuild Physical Disk
Use the following omconfig command syntax to rebuild a failed physical disk.
Rebuilding a disk may take several hours. If you need to cancel the rebuild,
use the Cancel Rebuild task. See the Dell OpenManage Online Help for more
information about Rebuild Physical Disk.
Complete Syntax
omconfig storage pdisk action=rebuild controller=
id pdisk=<PDISKID>
where id is the controller ID. The <PDISK> variable specifies the
physical disk.