Dell OpenManage Server AdministratorVersion 7.4 Command Line Interface Guide
oromconfig mainsystem temps index=0 warnthresh=defaultYou cannot default one value and set another. In other words, if you set the minimum warning thr
oromconfig mainsystem volts index=0 minwarnthresh=1.900 maxwarnthresh=2.250When you issue the command and the system sets the values you specify, the
Omconfig Preferences MessagesUse the omconfig preferences messages command to select the format of alert messages. The default format is traditional,
name=value pair 1 name=value pair 2 Description128bitorhigher: Sets the encryption levels to 128-bit or higher.attribute=seturl host=<string> po
For example, if a fan probe on the system reads a fan RPM of 300 and your minimum warning threshold value for that fan probe is 600 RPM, then the syst
Table 40. Valid Parameters Of Events for Alert ActionsEvent Name Descriptionevent=batterywarn Sets actions when a battery probe detects a warning valu
Event Name Descriptionevent=storagesyswarn Sets actions when a storage system detects a warning value.event=storagesysfail Sets actions when a storage
Example Chassis Intrusion ActionsTo clear all alert actions for chassis intrusion, type:omconfig system alertaction event=intrusion clearall=trueoromc
name=Value Pair Descriptionfalse: Disables an individual platform event filter.index=number Sets the index for the destination.ipaddress=<ipv4 addr
Components And Events Of Platform EventsThe following table lists the components and the events for which you can set platform events. Components are
1IntroductionDell OpenManage Server Administrator (OMSA) provides a comprehensive, one-to-one systems management solution through either an integrated
Event Name Descriptionevent=redunlost Sets action or enables or disables alert generation when the system fans and/or power supplies become inoperativ
• IndexSourceAt present, source=snmptraps is a required name=value pair because SNMP is currently the only supported source of event notification for
Table 45. System Event Severity ParametersCommand Result Descriptionomconfig system events type=<component name> severity=info or omconfig serve
Table 46. Valid Parameters Of Web Server Configurationname=value pair Descriptionaction=start Starts the Web server.action=stop Stops the Web server.a
system before powering the system down. If you do not want to shut down the operating system first, use the osfirst=false parameter. The following tab
name=value pair Descriptiona chassis reads a temperature (in degree Celsius) that exceeds the maximum temperature failure threshold value.Example Ther
116
5Omconfig System Or Servermodule Assetinfo: Editing Cost Of Ownership ValuesThe omconfig system assetinfo or omconfig servermodule assetinfo command h
Command Level 1Command Level 2Command Level 3Name= Value Pair 1Name= Value Pair 2 Descriptionthat acquired the system.expensed=yes | no Whether the sy
The following message is displayed:Asset information set successfully.You can type more than one omconfig system assetinfo or omconfig servermodule as
– VMware vSphere 5.5• Added support for the following browsers:– Mozilla Firefox 22 and 23– Internet Explorer 11– Safari 6.0– Google Chrome 27, 28, an
Example Command For Adding Depreciation InformationTo provide a value for a depreciation parameter, type a command of the form: omconfig system asseti
Example Command For Adding Extended Warranty InformationTo provide a value for an extended warranty parameter, type a command of the form: omconfig sy
Example Command For Adding Lease InformationTo provide a value for a lease parameter, type a command of the form: omconfig system assetinfo info=lease
The following message is displayed:Asset information set successfully.You can type more than one omconfig system assetinfo or omconfig servermodule as
For an example, see Example Command For Adding Acquisition Information.Adding Owner InformationThe owner is the party that holds legal property title
Table 58. Valid Parameters Of omconfig system assetinfo info=service Or omconfig servermodule assetinfo info=serviceCommand Level 1Command Level 2Comm
Command Level 1Command Level 2Command Level 3Name= Value Pair 1Name= Value Pair 2 Descriptionmail address, or website address.outsourced=true | false
Table 60. Valid Parameters Of omconfig system assetinfo info=system Or omconfig servermodule assetinfo info=systemCommand Level 1Command Level 2Comman
Command Level 1Command Level 2Command Level 3Name= Value Pair 1Name= Value Pair 2 Descriptionenddate=<enddate> Date the warranty agreement ends.
6Using The Storage Management ServiceThe CLI of Storage Management enables you to perform reporting, configuration, and management functions of Storag
– M820VRTX • Deprecated support for the following operating systems:– SUSE Linux Enterprise Server 10 SP4– SUSE Linux Enterprise Server 11 SP2– Red Ha
In this example, the id in controller=idis the controller number such that controller 1 is specified as controller=1.Syntax Of Command ElementsThe omr
Syntax DescriptionFor example, the name=<string>parameter is specified as name=VirtualDisk1.[ ]The bracket symbols ([ ]) indicate optional eleme
132
7Omreport Storage CommandsThe omreport command allows you to view storage component information for disks, controllers, enclosures, batteries, global
Command Level 1Command Level 2Command Level 3Usefluidcachepool Displays fluid cache pool properties.partition Displays the partition details of the sp
Table 66. omreport Virtual Disk CommandsRequired Command Levels (1, 2, 3)Optional name=value pairs Useomreport storage vdisk Displays property informa
Required Command Levels (1, 2, 3)Optional name=value pairs Useis the controller number and <ENCLOSUREID>is the enclosure ID. Example for SCSI co
Table 70. Omreport Fan StatusRequired Command Levels (1, 2, 3) and name=value pairOptional name=value pairs Useomreport storage enclosure Displays pro
Required Command Levels (1, 2, 3) and name=value pairOptional name=value pairs Useinfo=pwrsupplies index=n where id is the controller number and ENCLO
Table 73. Omreport Enclosure Slot Occupancy Report CommandsRequired Command Levels (1, 2, 3) and name=value pairOptional name=value pairs Useomreport
NOTE: For an overall summary of the CLI commands, type omhelp.NOTE: The omupdate commands are no longer supported in Server Administrator and are repl
Required Command Levels (1, 2, 3)Optional name=value pairs UseOpenManage Server Administrator Storage Management User’s Guide at dell.com/support/manu
Table 78. omreport PCIe SSD CommandRequired Command Levels (1, 2, 3) And name=value pairOptional name=value pairs Useomreport storage pciessdDisplays
Table 82. omreport Fluid Cache Disk CommandRequired Command Levels (1, 2, 3) And name=value pairUseomreport storage fluidcachediskDisplays the propert
8Omconfig Storage CommandsThe omconfig commands allows you to configure physical disks, virtual disks, controllers, enclosures, batteries, global info
Omconfig Physical Disk CommandsThe following sections provide the omconfig command syntax required to execute physical disk tasksTable 85. Omconfig Ph
NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller=ID to dis
Example to Prepares physical disk 3 on connector 0 of controller 1 for removal. On a SAS controller, the physical disk resides in enclosure 2.Example
Example for SCSI, SATA, and ATA controllersomconfig storage pdisk action=cryptographicerase controller=1 pdisk=0:3Example for SAS controllers omconfig
Omconfig Online Physical DiskDescriptionBrings an offline physical disk back online.Syntaxomconfig storage pdisk action=online controller=id pdisk=<
information about Rebuild Physical Disk, see the Dell OpenManage Online Help .Syntaxomconfig storage pdisk action=rebuild controller=id pdisk=<PDIS
Commandomconfig chassis volts index=3 minwarnthresh=3.3000MessageError! Number with up to 3 digits after decimal point expected, read 3.3000The value
Omconfig Cancel Replace MemberDescriptionCancels a replace member operation.Syntaxomconfig storage pdisk action=cancelreplacemember controller=id pdis
NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller=ID to dis
Example for SAS controllers omconfig storage pdisk action=disabledevicewritecache controller=1 pdisk=0:2:3Omconfig Export Reliability LogDescriptionEx
Omconfig Convert Non-RAID To RAIDDescriptionConverts non-RAID to RAID on a physical disk.Syntaxomconfig storage pdisk action=convertnonraidtoraid cont
Required Command Levels (1, 2, 3)Optional name=value pairsaction=fastinit controller=id vdisk=id [force=yes]action=slowinit controller=id vdisk=id [fo
Omconfig Cancel Check ConsistencyDescriptionCancels a check consistency while in progress.Syntaxomconfig storage vdisk action=cancelcheckconsistency c
Omconfig Blink Virtual DiskDescriptionBlinks the physical disks included in a virtual disk.Syntax omconfig storage vdisk action=blink controller=id vd
CAUTION: You may receive a warning message if you attempt to delete the system or boot partition. However, this warning message is not generated alway
NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller=ID to dis
CAUTION: Deleting a virtual disk destroys all information including file systems and volumes residing on the virtual disk. You may receive a warning m
The next level of complexity includes commands that contain command levels 1 and 2. All of the about commands are examples of command level 2 complexi
NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller=ID to dis
Omconfig Change Virtual Disk PolicyDescription Changes a virtual disk’s read, write, or cache policy.Syntaxomconfig storage vdisk action=changepolicy
NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller=ID to dis
omreport storage vdisk controller=ID to display the IDs for the virtual disks attached to the controller.Example to Reactivate fluid cache on virtual
Required Command Levels (1, 2, 3)Optional name=value pairsNOTE: If you set escrow=yes, specify the escrow file path.action=changesecuritykey controlle
Omconfig Rescan ControllerDescription Rescans a controller. For more information, see the Dell OpenManage Online Help .Syntax omconfig storage control
omconfig Test Controller AlarmTable 90. omconfig Test Controller AlarmDescription Tests the functionality of the controller alarm. The alarm sounds fo
where connector:enclosureID:targetID is the connector number, enclosure number, and slot number.• For SAS controllers:pdisk=connector:targetIDwhere co
Table 91. Parameters And TypesParameters Typecontroller=id Requiredraid=<c | r0 | r1 | r1c | r5 | r6 | r10 | r50 | r60> Requiredsize=<number
Table 93. Size Parametersize=<number | max | min> Parameter SpecificationDescriptionsize=<n> Use this specification to indicate a specific
2Using The omhelp CommandThe omhelp command and its equivalent, <command> -?, accesses the detailed help-text interface of Command Line Interfac
Table 95. Disk Cache Policy ParametersDisk Cache Policy diskcachepolicy=disabled | enabled Parameter SpecificationDisabled diskcachepolicy=disabledEna
Table 98. Raid Level And ConcatenationRAID Level or Concatenation raid=n Parameter SpecificationRAID-0 raid=r0RAID-1 raid=r1RAID-5 raid=r5RAID-6 raid=
Some controllers allow you to remove a physical disk from a virtual disk. In this case, do not specify to remove the physical disk.The pdisk=<PDISK
Table 103. Write Policy ParametersWrite Policy writepolicy=wb | wt | wc | fwb | nwc Parameter SpecificationWrite-back cache writepolicy=wbWrite-throug
rebuildrate=<rate> clearredundantpath=clear abortcheckconsistencyonerror=<enabled | disabled> loadbalance=<auto | disabled> allowrev
NOTE: If you set escrow=yes, specify the escrow file path.Omconfig Change Encryption KeyDescriptionChanges the encryption key for the controller, if p
Example to Set the reconstruct rate to 50 on controller 1.Exampleomconfig storage controller action= setreconstructrate controller=1 rate=50Omconfig S
Omconfig Import Foreign ConfigurationDescriptionImports all virtual disks that reside on physical disks newly attached to the controller.Syntax omconf
spinupstarttime=<HH:MM:AM/PM> spinuptimeinterval= <1 to 24>(hours), where id is the controller ID as reported by the omreport storage cont
Omconfig Create CachecadeDescriptionCreates a cachecade on the given controller.Syntaxomconfig storage controller action=createcachecade controller=id
The CLI responds with the following message:Asset information set successfully.When you type omconfig system assetinfo -?, the help that displays prov
Example to Convert multiple non-RAID to RAID on controller 0.Example omconfig storage controller action=convertnonraidtoraid controller=0 pdisk=0:2:3O
Example for SCSI, SATA, and ATA controllers omconfig storage enclosure action=enablealarm controller=1 enclosure=2Example for SAS controllers omconfig
Example for SCSI, SATA, and ATA controllers omconfig storage enclosure action=setassetname controller=1 enclosure=2 assetname=encl43Example for SAS co
Omconfig Set All Temperature Probe ThresholdsTable 111. Omconfig Set All Temperature Probe ThresholdsDescription Sets the minimum and maximum warning
Omconfig Battery CommandsThe following table displays the omconfig command syntax required to execute battery tasks.Table 114. Omconfig Battery Comman
Table 117. Omconfig Global CommandsRequired Command Levels (1, 2, 3)Optional name=value pairsomconfig storage globalinfoaction=enablestsaction=disable
Omconfig Global Rescan ControllerDescription Rescans all the controllers on the system. For more information about Global Rescan Controller, see the D
NOTE: This command is not supported on SAS controllers.Syntaxomconfig storage connector action=rescan controller=id connector=id, where id is the cont
Example to Unblinks the physical disk in cachecade 4 on controller 1Exampleomconfig storage cachecade action=unblink controller=1 cachecade=4Omconfig
Example omconfig storage cachecade action=rename controller=1 cachecade=4 name=cc4Omconfig PCIe SSD CommandsThe following table displays the omconfig
3omreport: Viewing System Status Using The Instrumentation ServiceThe omreport command allows you to see detailed information about the system compone
Example to Reactivate the specified PCIe SSD device.Example omconfig storage pciessd action=reactivate subsystem=2 pciedevice=0:2:0 force=yesOmconfig
Omconfig Fluid Cache Disk CommandThe following section provide the omconfig command syntax required to execute the fluid cache disk task.Table 124. Om
9Working With CLI Command ResultsServer Administrator Command Line Interface (CLI) users can use the command output in various ways. This chapter expl
Writing Command Output To A FileWhen redirecting command results to a file, you can specify a filename (and a directory path if necessary) to which yo
Maximum Warning Threshold : 5500RPMMinimum Failure Threshold : 500RPMMaximum Failure Threshold : 6000RPMYou cannot refer to the previous command resul
Minimum Failure Threshold: 500RPMMaximum Failure Threshold: 6000RPMYou can use a text editor to insert the time that each block of data was captured.
No special formatting option is required because list format is the default display format. The network data part of the example system summary is dis
Custom Delimited Format (cdv)Use the cdv formatting option to report exported data in custom delimited format. You can specify this option with any om
Notes, Cautions, and WarningsNOTE: A NOTE indicates important information that helps you make better use of your computer.CAUTION: A CAUTION indicates
Command Summary Of The omreport CommandDepending on the system configuration, the results of the omreport command vary from one system to another. Dat
Command Level 1Command Level 2Command Level 3User Privilege RequiredUseNonmasking Interrupt (NMI) button (if present on the system), are enabled or di
Command Level 1Command Level 2Command Level 3User Privilege RequiredUsevolts U, P, A Displays the status and thresholds for the system voltage sensors
Command Level 1Command Level 2Command Level 3User Privilege RequiredUsethrmshutdownP, A Displays how to perform the shutdown action, if any, when a te
Attribute : Express Service CodeValue : 18955029124CMC InformationAttribute : ProductValue : Chassis Management Controller (CMC)Attribute : Descri
Contains:Instrumentation Service 7.x.xStorage Management 4.x.xSun Java Runtime Environment 1.x.x_xxSecure Port Server 7.x.xServer Administrator Core F
Redundancy Status : FullNumber of devices required for full redundancy: 2Redundancy Mode :Redundancy Configuration : Input Source Line 1, upon redund
NOTE: To maintain consistency across the commands, the output format of this command has changed. Change the user scripts as applicable.To view the BI
Parameter DescriptionDual NIC (1/2) Displays whether NIC 1 and NIC 2 with PXE/iSCSI is enabled or disabled.Dual NIC (3/4) Displays whether NIC 3 and N
Parameter DescriptionOptical Drive Controller Displays whether the optical drive controller is enabled or disabled.Parallel port address Displays whet
Contents1 Introduction... 11What's New
Group DescriptionEmbedded Server ManagementSets up the Embedded Server Management options.Integrated Devices Controls the devices integrated on the sy
NOTE: To maintain consistency across the commands, the output format of this command has changed. Change the user scripts as applicable.NOTE: If iDRAC
Probe Name : System Board Power Optimized Status : NormalCause : [N/A]Omreport Chassis Info Or Omreport Mainsystem InfoUse the omreport chassis info o
Probe Name : Intrusion State : Chassis is closedOmreport Chassis Leds Or Omreport Mainsystem LedsUse the omreport chassis leds or omreport mainsyste
Error Correction : Multibit ECCTotal of Memory Array(s)Total Installed Capacity : 65536 MBTotal Installed Capacity Available to the OS : 64386 MBTot
If you specify the index, Server Administrator displays a summary for a specific memory module displaying the health, status, device name, type, speed
oromreport mainsystem nics config=team index=nNOTE: This command is applicable only if Team interface is configured in the system. Team interface is c
Server Administrator displays values for the following fields: Index, Status, Connector Name, Processor Brand, Processor Version, Current Speed, State
The following fields are defined for a cache present on a particular microprocessor. If the cache is internal to the processor, the fields do not appe
Field DescriptionCache Device Supported TypeType of static random access memory (SRAM) that the device can support.Cache Device Current Type Type of t
Omreport Chassis Processors Or Omreport Mainsystem Processors...36Omreport Chassis Pwrmanagement Or Omreport Main
The following is an example output:Power Inventory and Budget Power Inventory System Idle Power : 92 W System Maximum Potential Power : 344 WPower B
NOTE: The omreport chassis pwrmonitoring or omreport mainsystem pwrmonitoring command is applicable from PowerEdge 10G system onwards that support PMB
Peak Reading : 2.5 ANOTE: Power Management features are only available for PowerEdge systems that have hot-swappable power supplies and not systems t
name=value pair Descriptionconfig=serial Reports serial port information for BMC or remote access.config=serialoverlanReports BMC/iDRAC or remote acce
State : PresentAvailable Size : 472 MBStorage Size : 512 MBOmreport Chassis Slots Or Omreport Mainsystem SlotsUse the omreport chassis slots or omr
oromreport mainsystem volts index=nThe index parameter is optional. If you do not specify the index, Server Administrator displays a summary of status
If the system has both a main system chassis or main system and at least one direct attached storage device, Server Administrator may display a summar
Alert actions determine how Server Administrator responds when a component has a warning or failure event.The omreport system alertaction or omreport
• Physical Disk Warning• Physical Disk Failure• Virtual Disk Warning• Virtual Disk Failure• Enclosure Warning• Enclosure Failure• Storage Controller B
Disable: Informational, Warning, and Critical---------------------Removable Flash Media---------------------SettingsEnable: Informational, Warning and
Omconfig Chassis Leds Or Omconfig Mainsystem Leds...86Omconfig Chassis Memorymode Or Omconfig
Disable: None-----------Fans Group----------SettingsEnable: Informational, Warning, and CriticalDisable: None-----------Individual Objects-----------S
Output Attributes DescriptionDestination Number: Destination 2destination 2: Displays the second destination.Example:110.120.130.140: IPv4 address of
NOTE: To maintain consistency across the commands, the output format of this command has changed. Change the user scripts as applicable.Omreport Syste
: Data Engine x.x.x : Hardware Application Programming Interface x.x.x : Instrumentation Servicex.x.x : Instrumentation Service Integration Layer x.x.
Express Service Code 26790524560Slot Number Slot =8Slot Name SLOT-02Form Factor 1U Half WidthNode Id CB2DX1ScRemote Access Information Remote Access
Version : 1.50.50 (Build 3)Firmware Information Name : Lifecycle Controller 2Version : 1.3.0.518--------------- Remote Access Controller ----------
System Attributes• Host Name• System Location• Life Cycle ControllerMain System Chassis Or Main SystemChassis• Chassis Model• Chassis Service Tag• Exp
• BIOS Version• Release DateFirmware• Name• VersionNetwork DataThe following details are listed for each NIC and Team interface, if Team interface is
The output that is displayed in the CLI window depends on the version of the BIOS, RAID controllers, and firmware installed on the system. The followi
Table 17. Valid Parameters Of Omreport Preferences Webservername=value pair Descriptionattribute=geturl Reports the URL information of the Web server.
Adding Support Information... 125Example Com
4Omconfig: Managing Components Using The Instrumentation ServiceThe omconfig command allows you to provide values that define warning events, configur
omconfig Command SummaryThe following table provides a high-level summary of the omconfig command. The columns titled Command level 2 and Command leve
Command Level 1Command Level 2Command Level 3User Privilege RequiredUsealertlog P, A Allows the administrator to clear the alert log.assetinfo P, A En
Command Level 1Command Level 2Command Level 3User Privilege RequiredUse(DDDC) memory modes, and also specify which mode to use.pwrmanagementP, A Allow
Command Usage Descriptionomconfig system shutdown -?To display the list of valid parameters for omconfig system shutdown.omconfig system alertaction -
Secure Port Server 1.x.xServer Administrator Framework 6.x.xAgent for Remote Access 1.x.xStorage Management 3.x.x Sun Java Runtime Environment 1.x.xxO
name=value pair 1 attribute= name=value pair 2 setting= Description• immediate: System returns to previous state immediately.• timedelay <value>
name=value pair 1 attribute= name=value pair 2 setting= DescriptionNOTE: On Linux systems, user or user groups upgraded to administrator or administra
name=value pair 1 attribute= name=value pair 2 setting= Description• disabled: Disables XD support on system.attribute=cpucore setting=1 | 2 | 4 | 6 |
Omconfig Online Physical Disk... 148Omconfig Assign Glo
name=value pair 1 attribute= name=value pair 2 setting= Description• nic1isci: Enables iSCSI on the first NIC and none (no PXE or iSCSI) on the second
name=value pair 1 attribute= name=value pair 2 setting= Description• 19200: Sets the console redirection failsafe baud rate to 19200 bits per second.•
name=value pair 1 attribute= name=value pair 2 setting= Description• disabled: Disables the first NIC during system boot.• enabledonly: Enables the fi
name=value pair 1 attribute= name=value pair 2 setting= Descriptionattribute=nic4 setting=enabled | enabledwithpxe | disabled | enabledonly | enabledn
name=value pair 1 attribute= name=value pair 2 setting= Descriptionattribute=primaryscsi setting=on | off force=trueCAUTION: If you modify the setting
name=value pair 1 attribute= name=value pair 2 setting= Description• auto: Automatically enables the SATA port.attribute=secondaryscsi setting=on | of
name=value pair 1 attribute= name=value pair 2 setting= Description• com1bmc: Maps serial port 1 to COM port 1 bmc.NOTE: This command is applicable on
name=value pair 1 attribute= name=value pair 2 setting= DescriptionNOTE: Depending on the system's hardware you can configure either usb or usbb.
Group name=value pair 1 attribute= name=value pair 2 setting=attribute=InternalUsb1 setting=On | Offattribute=InternalUsb2 setting=On | Offattribute=I
Group name=value pair 1 attribute= name=value pair 2 setting=Processor Settingsattribute=DataReuse setting=Enabled | Disabledattribute=DcuIpPrefetcher
Omconfig Reset Controller Configuration... 166omconfig Create Virtual Dis
Group name=value pair 1 attribute= name=value pair 2 setting=attribute=ProcVirtualization setting=Enabled | Disabledattribute=QpiBandwidthPriority set
Group name=value pair 1 attribute= name=value pair 2 setting=attribute=SataPortG setting=Off | Autoattribute=SataPortGCapacity setting=<string>a
Group name=value pair 1 attribute= name=value pair 2 setting=attribute=MemVoltsetting=AutoVolt | Volt15V | Volt135VNOTE: Volt15V represents 1.5 Volt a
Omconfig Chassis Currents Or Omconfig Mainsystem CurrentsNOTE: This command is no longer available through Server Administrator.Omconfig Chassis Fans
oromconfig mainsystem fans index=0 minwarnthresh=4580 maxwarnthresh=9160When you issue the command and the system sets the values you specify, the fol
name=value pair 1 name=value pair 2Descriptionpowerbutton=enable | disableNA• true: Enables the Power button on the system.• false: Disables the Power
oromconfig mainsystem info index=0 tag=buildsysIndex 0 always defaults to the main system chassis. The following command omits index=n, but accomplish
Spare mode disables a bank of system memory in which a correctable memory event is detected, enables the spare bank, and copies all the data from the
name=value pair 1 Descriptionadvanced ECC (advecc): Enables the two DRAM controllers to combine in 128-bit mode and provide optimized reliability. Mem
name=value pair 1 name=value pair 2 Descriptionpower management controlled by the operating system.custom: This profile allows you to configure indivi
Omconfig Set Hot Spare Protection Policy... 186Omconfig Connector Commands
Table 29. Valid Parameters Of Omconfig Chassis Pwrmonitoring Or Omconfig Mainsystem Pwrmonitoringname=value pair 1 name=value pair 2 Descriptionindex=
Omconfig Chassis Remoteaccess Or Omconfig Mainsystem RemoteaccessUse the omconfig chassis remoteaccess or omconfig mainsystem remoteaccesscommand to c
name=value pair 1 config=name=value pair 2 DescriptionNOTE: The enablenic option is supported on PowerEdge 9G systems that have DRAC 5 installed.nicse
name=value pair 1 config=name=value pair 2 DescriptionNOTE: The failovernw option is supported on PowerEdge12G systems onward. Configure both primaryn
name=value pair 1 config=name=value pair 2 Descriptionvlanpriority=numbernumber: Priority of virtual LAN identification in the range of 0 to 7.privile
name=value pair 1 config=name=value pair 2 Descriptionmodembasic | modemterminal | modembasicterminalnumber of text commands over a serial connection.
name=value pair 1 config=name=value pair 2 Descriptionoperator: Sets the maximum privilege level that are accepted on a serial over LAN channel, to Op
name=value pair 1 config=name=value pair 2 Descriptionenableserialoverlan=true: Enables serial over LAN.enableserialoverlan=false: Disables serial ove
name=value pair 1 config=name=value pair 2 Descriptiondracusergroup=custom: Enables the Custom User privileges.NOTE: For more information on dracuserg
name=value pair 1name=value pair 2 name=value pair 3 Descriptionaccessvirtualmedia=true | falsetrue or false: Enables or disables access to virtual me