Dell Chassis Management Controller Version 1.0 for PowerEdge VRTX Guía de usuario Pagina 112

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 155
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 111
To use this object property for, you must have Chassis Configuration Administrator privileges.
NOTE: You can configure any setting that is not preceded by the hash sign (#) in the output. To modify a
configurable object, use the -o option.
The following sections provide information about the objects in the cfgEmailAlert group.
cfgEmailAlertIndex (Read Only)
Description The unique index of an alert instance.
Legal Values 1-4
Default <
instance
>
cfgEmailAlertEnable (Read/Write)
Description Enables or disables the alert instance.
Legal Values
1 (TRUE)
0 (FALSE)
Default 0
cfgEmailAlertAddress (Read/Write)
Description Specifies the destination email address for email alerts,
for example, [email protected].
Legal Values E-mail address format, with a maximum length of 64 ASCII
characters.
Default <
blank
>
cfgEmailAlertEmailName
Description Specifies name or other identifier associated with the
destination e-mail address. The e-mail name can refer to
an individual, group, location, department, and so on.
Legal Values A string of up to 32 characters
Default <
blank
>
Example
racadm getconfig -g cfgEmailAlert -i 2
# cfgEmailAlertIndex=1
cfgEmailAlertEnable=1
cfgEmailAlertName=Kevin Fulton
112
Vista de pagina 111
1 2 ... 107 108 109 110 111 112 113 114 115 116 117 ... 154 155

Comentarios a estos manuales

Sin comentarios