Vista de pagina 42
omreport: Viewing System Status Using the Instrumentation Service 43
omreport chassis acswitch
Use the omreport chassis acswitch command if your system has redundant power supplies that are
configured in a failover arrangement. When you type:
omreport chassis acswitch
Server Administrator displays the following output:
Server Administrator reports values for the Redundancy Status and Redundancy Mode fields.
omreport chassis bios
Use the omreport chassis bios command to view current BIOS information. When you type:
omreport chassis bios
Server Administrator displays a summary of your system’s BIOS information.
AC Failover Switch
AC Switch Redundancy
Redundancy Status : Full
Number of devices required for full
redundancy
:2
Redundancy Mode :
Redundancy Configuration : Input Source Line 1,
upon redundancy restoration, return to Line 1
AC Power Lines
Status : Ok
Location : AC Power Line 1
AC Present : Power Present
Active Source : Active
Status : Ok
Location : AC Power Line 2
AC Present : Power Present
Active Source : Not Active