Dell v1.1 Manual de usuario Pagina 124

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 175
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 123
NOTE: To use this command, you must enter the local system credentials.
Sample-Generic Command Local—Enable this use case to run a command or script on system with
OpenManage Essentials.
NOTE: To use this command, you must enter the local system credentials.
Sample-IPMI Command—Enable this use case to receive information about the power status of a server.
Sample-Remote Command—Enable this use case to view the system summary through Server Administrator.
Sample RACADM-Clear SEL Log—Enable this use case to clear the SEL log of RAC.
Sample-RACADM-Reset—Enable this use case to reset the RAC.
Device Capability Matrix
The device capability matrix below provides information about the type of remote tasks supported on devices that are
displayed in the Task Target tab.
Remote Task
Type
All Servers
(except ESXi)
With Server
Administrator and
Discovered Using
SNMP/WMI [a]
Windows-based
Servers without
Server
Administrator and
discovered using
WMI [a]
Linux-based
Servers without
Server
Administrator and
discovered using
SSH [a]
DRAC/iDRAC
discovered using
IPMI [b]
DRAC/iDRAC
discovered using
SNMP/Ws-Man
[b]
Reboot/power
cycle operation
Supported Supported Not supported Not supported Not supported
Power off
operation
Supported Supported Not supported Not supported Not supported
Power on
operation
Not supported Not supported Not supported Supported Not supported
Remote Server
Administrator
command task
Supported Not supported Not supported Not supported Not supported
IPMI command
task
Not supported Not supported Not supported Not supported Not supported
RACADM
command line
task
Not supported Not supported Not supported Not supported Supported
[a] DRAC/iDRAC is not discovered.
[b] Server operating system is not discovered.
Device capabilities for a server or DRAC/iDRAC device are populated during discovery and is leveraged by remote tasks
to determine applicable targets for each task type. The capability is populated based on the following parameters:
Protocol used to discover the server and DRAC/iDRAC. For example, IPMI, SNMP, and so on.
If Server Administrator is installed on the server.
Settings enabled on the DRAC/iDRAC.
Selecting the Enable All check box allows you to override device capability and allows all the available devices for
selection as task targets.