Dell PowerEdge 4400 Manual de usuario

Busca en linea o descarga Manual de usuario para Hardware De La Computadora Dell PowerEdge 4400. Dell PowerEdge 4400 User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 89
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
Dell™PowerEdge™4400SystemsUser'sGuide
Information in this document is subject to change without notice.
©1999 Dell Computer Corporation. All rights reserved.
Reproduction in any manner whatsoever without the written permission of Dell Computer Corporation is strictly forbidden.
Trademarks used in this text: Dell, the DELL logo, Dell OpenManage, and PowerEdge are trademarks and DellWare is a service mark of Dell Computer Corporation; Intel,
i960, and Pentium are registered trademarks and MMX, Xeon, and Intel386 are trademarks of Intel Corporation; Microsoft, Windows, MS-DOS, and Windows NT are registered
trademarks of Microsoft Corporation; Novell and NetWare are registered trademarks of Novell, Inc.; ASPI is a registered trademark of Adaptec, Inc.; VESA is a registered
trademark and VL-Bus is a trademark of Video Electronics Standards Association; Adobe is a trademark of Adobe Systems Incorporated, which may be registered in certain
jurisdictions; OS/2 is a registered trademark of International Business Machines, Inc.
Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Dell Computer Corporation
disclaims any proprietary interest in trademarks and trade names other than its own.
Initial release: 10 Sep 1999
Last revised: 4 Nov 1999
Safety Instructions
Preface
Introduction
Using the Dell OpenManage Server Assistant CD
Installing and Configuring SCSI Drivers
Using the System Setup Program
Using the Resource Configuration Utility
Technical Specifications
I/O Ports and Connectors
Maintaining the System
Regulatory Notices
Warranty, Return Policy, and Year 2000 Statement of Compliance
Glossary
Model SML
Vista de pagina 0
1 2 3 4 5 6 ... 88 89

Indice de contenidos

Pagina 1

Dell™PowerEdge™4400SystemsUser'sGuide Information in this document is subject to change without notice. ©1999 Dell Computer Corporation. A

Pagina 2 - User's Guide

A pop-up menu appears, listing the options for that category. To select an option, press the up- or down-arrow key to highlight the option and press &

Pagina 3 - Utility Partition

Exit From This Utility The Exit from this utility option allows you to exit from the RCU and reboot your computer system. Advanced Menu The Advanced

Pagina 4 - Video Driver

Back to Contents Page Glossary:Dell™PowerEdge™4400SystemsUser'sGuide A •B •C •D •E •F •G •H •I •J •K •L •M •N •O •P •Q •R

Pagina 5 - Asset Tag Utility

to the configuration of your computer, you should back up important start-up files, such as autoexec.bat and config.sys for MS-DOS or win.ini and syst

Pagina 6

bus A bus forms an information pathway between the components of a computer. Your computer contains an expansion bus that allows the microprocessor t

Pagina 7

A chip or expansion card that controls the transfer of data between the microprocessor and a peripheral such as a diskette drive or the keyboard. co

Pagina 8 - Main Menu

Acronym for Deutsche Industrie Norm. DIP Acronym for dual in-line package. A circuit board, such as a system board or expansion card, may contain DI

Pagina 9

Abbreviation for double-sided/double-density. DS/HD Abbreviation for double-sided/high-density. DTE Abbreviation for data terminal equipment. Any

Pagina 10

ESDI Acronym for enhanced small-device interface. expanded memory A technique for accessing RAM above 1 MB. To enable expanded memory on your comp

Pagina 11 - Resolving Resource Conflicts

GB Abbreviation for gigabyte(s). A gigabyte equals 1024 megabytes or 1,073,741,824 bytes. graphics coprocessor See coprocessor. graphics mode See

Pagina 12

Back to Contents Page Using the Dell OpenManage Server AssistantCD:Dell™PowerEdge4400SystemsUser's Guide Overview The Dell OpenManage Serve

Pagina 13

I/O Abbreviation for input/output. The keyboard and a printer, for example, are I/O devices. In general, I/O activity can be differentiated from comp

Pagina 14

Kbps Abbreviation for kilobit(s) per second. key combination A command requiring that you press multiple keys at the same time. For example, you ca

Pagina 15

mAh Abbreviation for milliampere-hour(s). math coprocessor See coprocessor. MB Abbreviation for megabyte(s). The term megabyte means 1,048,576 by

Pagina 16

MS-DOS Abbreviation for Microsoft Disk Operating System. MTBF Abbreviation for mean time between failures. multifrequency monitor A monitor that

Pagina 17

parallel port An I/O port used most often to connect a parallel printer to your computer. You can usually identify a parallel port on your computer b

Pagina 18

The set of diskettes from which you can perform a complete installation of an application program. When you reconfigure a program, you often need its

Pagina 19

RAID 10 is a mirroring technique in which data is duplicated across two identical RAID 0 arrays or hard-disk drives. All data on a physical drive in o

Pagina 20

SDMS Abbreviation for SCSI device management system. SDRAM Abbreviation for synchronous dynamic random-access memory. SDS Abbreviation for scalab

Pagina 21

switch See parameter. sync negotiation Sync negotiation is a SCSI feature that allows the host adapter and its attached SCSI devices to transfer da

Pagina 22

Abbreviation for thin film transistor. A flat-panel display for notebook computers where each pixel is controlled by one to four transistors. tpi Ab

Pagina 23

1. Click the SETUP icon at the top of the screen. 2. Click Express Setup. 3. Follow the directions on the screen to complete the installation and co

Pagina 24

Abbreviation for volt(s) direct current. VDE Abbreviation for Verband Deutscher Elektrotechniker. VESA Acronym for Video Electronics Standards Asso

Pagina 25

The most common way that virus programs move from one system to another is via "infected" diskettes, from which they copy themselves to the

Pagina 26

Back to Contents Page

Pagina 27

Back to Contents Page Introduction: Dell™PowerEdge™4400SystemsUser'sGuide Overview The Dell PowerEdge 4400, which has an Intel®Pentium®II

Pagina 28

l A single, 1.44-MB 3.5-inch diskette drive. l A 17/40x SCSI CD-ROM drive. The system board includes the following integrated features: l Seven PC

Pagina 29

Front Panel The following controls and indicators are behind the external drive door on the computer's front panel (see Figure 1). Figure 1. Fron

Pagina 30

Connecting External Devices You can connect various external devices, such as a mouse and printer, to the I/O ports and connectors on the computer’s b

Pagina 31

Back to Contents Page I/O Ports and Connectors: Dell™PowerEdge™4400SystemsUser'sGuide Overview This section provides specific information a

Pagina 32 - Back to Contents Page

The computer system has an autoconfiguration capability for the serial ports. This feature lets you add an expansion card containing a serial port tha

Pagina 33 - System Features

Keyboard and Mouse Connectors The system uses a Personal System/2 (PS/2)-style keyboard and supports a PS/2-compatible mouse. Cables from both devices

Pagina 34 - Supported Operating Systems

Running the System Diagnostics You can run the system diagnostics from the utility partition or from a diskette, but not from the Dell OpenManage Ser

Pagina 35 - Front Panel

 USB Connectors Your system contains two Universal Serial Bus (USB) connectors for attaching USB-compliant devices. USB devices are typically periphe

Pagina 36 - Getting Help

Back to Contents Page Maintaining the System: Dell™PowerEdge™4400SystemsUser'sGuide Overview Proper use of preventive maintenance procedures

Pagina 37 - Serial and Parallel Ports

To avoid these conditions, Dell recommends keeping your work environment clean to reduce the amount of dust and dirt around the system, thereby reduci

Pagina 38

Adequate ventilation is particularly important at high altitudes. System performance may not be optimum when the system is operating at high temperatu

Pagina 39 - Video Connector

system. l Keep components in their antistatic packaging until they are installed. l Avoid wearing clothing made of wool or synthetic materials. Ele

Pagina 40 - USB Connectors

l Use one of the power protection devices described in the following section, "Power Protection Devices." l Place the system on a dedicated

Pagina 41 - Cleaning System Components

Back to Contents Page Preface:Dell™PowerEdge™4400SystemsUser'sGuide About This Guide This guide is intended for anyone who uses the Dell Po

Pagina 42 - Environmental Factors

technical changes to the system or advanced technical reference material intended for experienced users or technicians. l Documentation updates are s

Pagina 43

Back to Contents Page RegulatoryNotices:Dell™PowerEdge™4400SystemsUser'sGuide Overview Electromagnetic Interference (EMI) is any signal o

Pagina 44

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: l This device may not cause harmful interfe

Pagina 45 - Power Protection Devices

5. Select the Settings tab. 6. Click Display Type and then click Change in the Adapter box. A list of available video drivers is displayed. 7. Clic

Pagina 46 - Other Documents You May Need

RF INTERFERENCE WARNING: This is a Class A product. In a domestic environment this product may cause radio frequency (RF) interference, in which case

Pagina 47 - Typographical Conventions

This is a Class B product based on the standard of the Voluntary Control Council for Interference (VCCI) for information technology equipment. If th

Pagina 48 - FCC Notices (U.S. Only)

A protection mark "B" confirms that the equipment is in compliance with the protection usage requirements of standards PN-93/T-42107 and PN-

Pagina 49 - CE Notice (European Union)

 BSMI Notice (Taiwan Only) Back to Contents Page Importador: DellComputerdeMéxico, S.A. de C.V. Rio Lerma No. 302 - 4°Piso Col. Cuauhtemoc 165

Pagina 50 - VCCI Notice (Japan Only)

Back to Contents Page Safety Instructions: Dell™ PowerEdge™ 4400 Systems User's Guide Overview Use the following safety guidelines to ensure you

Pagina 51

To reduce the risk of bodily injury, electrical shock, fire, and damage to the equipment, observe the following precautions. General Precautions Obser

Pagina 52

l Position cables and power cords carefully; route cables and the power cord and plug so that they cannot be stepped on or tripped over. Be sure that

Pagina 53 - BSMI Notice (Taiwan Only)

l Ensure that proper airflow is provided to components in the rack. l Do not step on or stand on any system/component when servicing other systems/c

Pagina 54 - PowerEdge

accumulated. You can also take the following steps to prevent damage from electrostatic discharge (ESD): l When unpacking a static-sensitive componen

Pagina 55 - Additional Safety Precautions

Back to Contents Page 1Monitor screen at or below eye level2Wrists relaxed and flat3Arms at desk level4Feet flat on the floor5Monitor and keyboard pos

Pagina 56

Table 2. Asset Tag Command-Line Options Back to Contents Page Asset Tag OptionDescription/dDeletes the asset tag number/?Displays the Asset Tag utilit

Pagina 57

Back to Contents Page Installing and Configuring SCSI Drivers: Dell™PowerEdge™4400SystemsUser'sGuide Overview This section describes how to

Pagina 58 - Ergonomic Computing Habits

Use the editor included with your operating system to view or print the readme.txt file or any other readme file. The SCSISelect Utility The BIOS for

Pagina 59

NOTE: For the full name of an abbreviation or acronym used in this table, see the "Glossary." SCSI Bus Interface Definitions The basic host

Pagina 60

mode. Synchronous data transfer is faster than asynchronous data transfer. The host adapter always responds to synchronous negotiation if the SCSI de

Pagina 61 - The SCSISelect Utility

l All Disks — All removable-media drives supported by the BIOS are treated as hard-disk drives. l Disabled — No removable-media drives are treated as

Pagina 62

Exiting SCSISelect To exit SCSISelect, press <Esc> until a message prompts you to exit. (If you changed any 78xx series host adapter settings, y

Pagina 63

These files are located in the \scsi directory on the Windows NT 4.0 Driver diskette. The driver is copied from the diskette to your system. 10.

Pagina 64

12. Select the adpu160.hamdriverandpress<Enter>. The system prompts you for a slot number for the device. 13. Press <Alt><Esc&g

Pagina 65

4. At the Driver Options menu, highlight Configure disk and storage device drivers and press <Enter>. 5. At the Additional Driver Actions menu,

Pagina 66

1. Load monitor.nlm to display the various options. 2. Select Disk Information. All system hard-disk drives appear. 3. Select the removable-media

Pagina 67 - Installation for NetWare 5.0

Back to Contents Page Using the Resource Configuration Utility: Dell™PowerEdge™4400SystemsUser'sGuide Overview The Resource Configuration U

Pagina 68 - Using SCSI Devices

Adaptec's adpu160.ham driver module is flexible enough to allow you to connect SCSI drives that are tested and approved for NetWare as well as st

Pagina 69

l 100-299 — Host-adapter specific l 300-999 — Reserved Specific error codes, such as those in the following subsections, appear only if you have in

Pagina 70 - Troubleshooting for NetWare

Back to Contents Page Using the System Setup Program: Dell™PowerEdge™4400SystemsUser'sGuide Overview Each time you turn on your computer sy

Pagina 71

l Configuration options — The box on the left half of both screens lists the options that define the installed hardware in your computer. Fields besi

Pagina 72 - System Setup Screens

If your system has RAID on motherboard (ROMB), Page 2 of the setup screen is as follows:

Pagina 73

System Setup Options The following subsections explain in detail each of the options on the System Setup screens. Time Time resets the time on the co

Pagina 74

Speaker Speaker determines whether the integrated speaker is On (the default) or Off. A change to this option takes effect immediately (rebooting the

Pagina 75 - System Setup Options

(drive 0). If the hard-disk drive is not bootable, the system tries to boot from the Plug and Play network adapters in the order found. Hard Disk Onl

Pagina 76

l COM1 (input/output [I/O] address 3F8h), which shares IRQ4 with COM3, is remapped to COM3 (I/O address 3E8h). l COM2 (I/O address 2F8h), which shar

Pagina 77

l The processor line displays the microprocessor type and speed. l Level 2 Cachedisplaysthesizeofthecache(256kilobytes[KB]).Advancedisdi

Pagina 78

Starting the RCU If you are running the RCU from your hard-disk drive, remove any terminate-and-stay-resident (TSR) programs from memory before starti

Pagina 79

The password setting changes to Enabled. Your system password is now set; you can exit the System Setup program and begin using your system. Note, ho

Pagina 80

password have full use of the System Setup program. To change an existing setup password, you must know the setup password (see "Deleting or Cha

Pagina 82

Back to Contents Page Technical Specifications: Dell™PowerEdge™4400SystemsUser'sGuide MicroprocessorVideoExpansion BusPowerMemoryPhysicalDr

Pagina 83 - Expansion Bus

Internally accessible: Ultra160/mSCSIcontroller two 68-pin connectors for internal or external SCSI drivesUltra/Narrow SCSI controller 50-pin co

Pagina 84 - Environmental

Back to Contents Page (onepulseoneachsideofthesystem)of41Gforupto2ms Storage (non-operational) six consecutively executed shock pulses

Pagina 85

Back to Contents Page Warranty,ReturnPolicy,andYear2000StatementofCompliance:Dell™PowerEdge™4400 Systems User's Guide Limited Three-Ye

Pagina 86

INCIDENTAL OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION ANY LIABILITY FOR PRODUCTS NOT BEING AVAILABLE FOR USE OR FOR LOST DATA OR SOFTWARE.

Pagina 87

OTHER RIGHTS, WHICH VARY FROM STATE TO STATE (OR JURISDICTION TO JURISDICTION). DELL DOES NOT ACCEPT LIABILITY BEYOND THE REMEDIES SET FORTH IN THIS W

Pagina 88

Software Dell specifically excludes all non-Dell-developed software from this compliance statement. All software run on Dell-branded hardware products

Pagina 89

When you select the Step 2: Add or remove boards option, the RCU lists all the expansion slots in your computer. (You may have to press <Page Down&

Comentarios a estos manuales

Sin comentarios