7
Technical Specifications
The Aggregator is an I/O module and installed with the Dell PowerEdge FX2 server chassis for
communication.
NOTE: Replace the battery only with same or equivalent type. Dispose of the batteries according to
the manufacturer's instructions.
Table 4. Environmental Parameters
Parameter Specifications
Operating temperature
20°C/h (36°F/h)
Storage temperature -40° to 158°F (-40° to 70°C)
Relative humidity (Storage)
5 percent to 95 percent RH with 33 °C (91 °F)
maximum dew point. Atmosphere must be non-
condensing always.
Maximum thermal output
475 BTU/hr
Maximum altitude
Operating
Storage
3048 m (10,000 ft)
12000 m (39,370 ft)
Table 5. Power Requirements
Parameter Specifications
Power supply 90–264 VAC 50/60 Hz
Maximum current draw per system 10A per power supply
Maximum power consumption 1920 W (high Line) 900 (low line)