6
Connect the expansion enclosures (if present) to the RAID controller
module you added in slot 1, as shown in Figure 2.
NOTE: Wait for the enclosure status LED to turn blue before proceeding
to the next step.
7
In MD Storage Manager, click the
Tools
tab (for the storage array you are
upgrading).
8
Select
Configure Ethernet Management Ports
, then select
Controller 1,
Port 1
in the
Ethernet port
menu.
9
Select
Specify configuration
.
10
Set the IP address, subnet mask, and gateway for Controller 1, Port 1.
11
Click
New
to add a new storage array.
12
In the
Add New Storage Array
window, select
Manual
and then click
OK
.
The
Add New Storage Array – Manual
window opens.
13
Select
Out-of-band management
.
14
In the
RAID Controller Module (host name or IP address)
fields, enter
the IP addresses of both the RAID controllers now in your storage enclosure.
Click
Add
.
When asked if you would like to add another storage array, click
No
.
15
Adjust the virtual disk caching options (in each example below, the
IP_address
is the management port address of RAID controller 0):
a
Display a list of all virtual disks:
SMcli IP_address -c “show allVirtualDisks;”
b
For each virtual disk name shown, run the following command:
SMcli IP_address -c “set
virtualDisk[virtual_disk_name]
mirrorCacheEnabled=true writeCacheEnabled=true
readCacheEnabled=true;”
Comentarios a estos manuales