Power
AC Power Supply (per power supply)
Wattage 495 W, 750 W, or 1100 W
Heat dissipation
NOTE: Heat dissipation is calculated using the
power supply wattage rating.
1908 BTU/hr maximum (495 W power supply)
2891 BTU/hr maximum (750 W power supply)
4100 BTU/hr maximum (1100 W power supply)
Voltage
NOTE: This system is also designed to be
connected to IT power systems with a phase to
phase voltage not exceeding 230 V.
100–240 V AC, autoranging, 50/60 Hz
DC Power Supply (per power supply) (when available)
Wattage 1100 W
Heat dissipation
NOTE: Heat dissipation is calculated using the
power supply wattage rating.
4416 BTU/hour maximum
Voltage -(48–60) V DC
Battery
Coin-cell battery 3 V CR2032 Lithium coin cell
Physical
Height 42.8 mm (1.68 inch)
Width 482.4 mm (18.99 inch) with rack latches.
434 mm (17.08 inch) without rack latches.
Depth 700.5 mm (27.58 inch)
Weight
Maximum Configuration 15.52 kg (34.14 lb)
Empty 8.58 kg (18.92 lb)
Environmental
NOTE: For additional information about environmental measurements for specific system configurations, see
dell.com/environmental_datasheets.
Temperature
Operating Continuous operation: 10 °C to 35 °C (50 °F to 95 °F) at
10% to 80% relative humidity (RH), with 26 °C max dew
point. De-rate maximum allowable dry bulb temperature
at 1 °C/300 m above 900 m (1°F per 550 ft).
7
Comentarios a estos manuales