104 Virtualization-Related Events
Dell - Redundancy
lost
A redundancy sensor
in the specified system
detected that one of
the components in the
redundant unit has
been disconnected,
has failed, or is not
present.
Error Put the system into
maintenance mode
Dell - Power supply
returned to normal
Sensor Returned to
Normal Value
Info No action
Dell - Power supply
detected a warning
A power supply sensor
reading in the
specified system
exceeded a user-
definable warning
threshold.
Warning No action
Dell - Power supply
detected a failure
A power supply has
been disconnected or
has failed.
Error Put the system into
maintenance mode
Dell - Power supply
sensor detected
anon-recoverable
value
A power supply sensor
in the specified system
detected an error from
which it cannot
recover.
Error No action
Dell - Memory
Device Status
warning
A memory device
correction rate
exceeded an
acceptable value.
Warning No action
Dell - Memory
Device error
A memory device
correction rate
exceeded an
acceptable value, a
memory spare bank
was activated, or a
multibit ECC error
occurred.
Error Put the system into
maintenance mode
Event Name Description Severity Recommended Action