Dell OpenManage Server Administrator Version 5.4 Manual de usuario Pagina 189

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 258
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 188
Using the Storage Management Service 187
omconfig Connector Commands
The following sections provide the omconfig command syntax required to
execute connector tasks.
omconfig Rescan Connector
Use the following omconfig command to rescan a controller connector. This
command rescans all connectors on the controller and is therefore similar to
performing a controller rescan.
NOTE: This command is not supported on SAS controllers.
Complete Syntax
omconfig storage connector action=rescan
controller=id connector=id
where id is the controller ID and the connector ID as reported by the
omreport command. To obtain these values, enter omreport storage
controller to display the controller IDs and then enter omreport storage
connector controller=ID to display the IDs for the connectors attached to
the controller.
Example Syntax
To rescan connector 2 on controller 1, enter:
omconfig storage connector action=rescan
controller=1 connector=2
Table 6-25. omconfig Connector Commands
Required Command Levels (1, 2, 3) Optional name=value pairs
omconfig storage connector
action=rescan controller=id connector=id
Vista de pagina 188
1 2 ... 184 185 186 187 188 189 190 191 192 193 194 ... 257 258

Comentarios a estos manuales

Sin comentarios