198 Working With CLI Command Results
You can use a text editor to insert the time that each block of data was
captured. In comparing the two snapshots for fan probe 0, you can see that
the second report shows several changes. The reading of fan RPM has
increased by 621 RPM but is still within normal range. Someone has raised
the minimum warning threshold by 200 RPM and has decreased the
maximum warning threshold by 2000 RPM.
Selecting a Format for Your CLI Command Output
You can specify a format for your CLI command results. The format
determines how the command output is displayed. If the command results
are directed to a file, the format is captured by the file to which you write your
command results.
NOTE: The omconfig command ignores most output format options and returns
plain text messages. However, if you choose to display in an XML format, the
omconfig command returns XML code.
The available formats include:
List (lst)
Semicolon-separated values (ssv)
Table (tbl)
Raw XML (xml)
Custom delimited format (cdv)
Minimum Warning Threshold : 600RPM
Maximum Warning Threshold : 5700RPM
Minimum Failure Threshold : 500RPM
Maximum Failure Threshold : 6000RPM
Index : 0
Status : OK
Probe Name : System Board Fan 1 RPM
Reading : 3001RPM
Minimum Warning Threshold : 700RPM
Maximum Warning Threshold : 5500RPM
Minimum Failure Threshold : 500RPM
Maximum Failure Threshold : 6000RPM