Dell OpenManage Server Administrator Version 6.0.1 Guía de usuario Pagina 187

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 780
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 186
Power Group 187
Table 8-14. AC Power Cord State Settings
Variable Name:
DellACPowerCordStateSettings
Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1) The AC power cord’s state is unknown.
online(2) The AC power cord’s state is disabled (offline) 0 or
enabled (online) 1.
notReady(4) The AC power cord’s state is not ready.
acPowerCordHasPower
(8)
The AC power cord has power.
acPowerCordIsActive
Source(16)
The AC power cord is the active source of
AC power.
Table 8-15. Battery Reading
Variable Name:
DellBatteryReading
Data Type: Integer
NOTE:
These values are bit masks, so combination values are possible.
Possible Data Values Meaning of Data Value
predictiveFailure(1) Battery sensor detects predictive failure.
failed(2) Battery has failed.
presenceDetected(4) Battery presence is detected.
book.book Page 187 Tuesday, January 27, 2009 12:37 PM