Dell OpenManage Server Administrator Version 6.0.1 Guía de usuario Pagina 686

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 780
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 685
686 Traps
Temperature Probe Failure
1054 Temperature sensor detected
a failure value
Sensor location:
<
Location in chassis
>
Chassis location: <
Name of
chassis
>
Previous state was: <
State
>
If sensor type is not
discrete:
Temperature sensor value (in
degrees Celsius):
<Reading>
If sensor type is discrete:
Discrete temperature state:
<State>
Error A temperature sensor
on the backplane
board, system board,
or drive carrier in the
specified system
exceeded its failure
threshold. The sensor
location, chassis
location, previous
state, and
temperature sensor
value are provided.
Temperature Probe Nonrecoverable
1055 Temperature sensor detected
a non-recoverable value
Sensor location:
<
Location in chassis
>
Chassis location: <
Name of
chassis
>
Previous state was: <
State
>
If sensor type is not
discrete:
Temperature sensor value (in
degrees Celsius):
<Reading>
If sensor type is discrete:
Discrete temperature state:
<State>
Error A temperature sensor
on the backplane
board, system board,
or drive carrier in the
specified system
detected an error
from which it cannot
recover. The sensor
location, chassis
location, previous
state, and
temperature sensor
value are provided.
Table 26-3. Temperature Probe Traps (continued)
Trap ID Description Severity Cause
book.book Page 686 Tuesday, January 27, 2009 12:37 PM
Vista de pagina 685