130 omconfig: Managing Components
Specify a Value for Minimum and Maximum Warning Thresholds
If you want to specify values for the temperature probe warning thresholds,
you must specify the number of the probe you are configuring and the
minimum and/or maximum warning threshold value. In the following
example, the probe that is being configured is probe 4:
omconfig chassis temps index=4 minwarnthresh=11.2
maxwarnthresh=58.7
or
omconfig mainsystem temps index=4 minwarnthresh=
11.2 maxwarnthresh=58.7
When you issue the command and the system sets the values you specify, the
following message appears:
Temperature probe warning threshold(s) set
successfully.
NOTE: In PowerEdge x8xx and x9xx systems, warning threshold for the
temperature probe can be set only for the ambient temperature.
omconfig chassis volts/omconfig mainsystem volts
Use the omconfig chassis volts or omconfig mainsystem volts command to
set voltage probe warning thresholds. As with other components, you can
view both warning and failure threshold values, but you cannot set failure
threshold values. Your system manufacturer sets the minimum and
maximum values for the failure thresholds.
Valid Parameters for Voltage Warning Thresholds
Table 4-15 shows the valid parameters for setting voltage warning
threshold values.
NOTE: Threshold values that you can set vary from one system configuration
to another.