Omconfig Instant Erase Secured Physical Disk
Description
Erases the given encrypted disk.
Syntax
omconfig storage pdisk
action=instantsecureerase controller=id
pdisk=<PDISKID>, where id is the controller ID. The
<PDISKID> variable specifies the physical disk.
NOTE: To obtain these values, type omreport storage
controller to display the controller IDs and then type
omreport storage pdisk controller=ID to display the
IDs for the physical disks attached to the controller.
Example to Erase physical disk 3 on connector 0 of controller 1. On a
SAS controller, the physical disk resides in enclosure 2.
Example for SCSI, SATA, and ATA controllers
omconfig storage pdisk
action=instantsecureerase controller=1
pdisk=0:3
Example for SAS controllers
omconfig storage pdisk action=remove
controller=1 pdisk=0:2:3
Omconfig Initialize Physical Disk
Description
Initializes a physical disk.
Syntax
omconfig storage pdisk
action=initialize controller=id
pdisk=id, where id is the controller ID and physical
disk ID as reported by the omreport command.
NOTE: To obtain these values, type omreport storage
controller to display the controller IDs and then type
omreport storage pdisk controller=ID to display the
IDs for the physical disks attached to the controller.
Example to Initialize physical disk 4 on controller 1
Example
omconfig storage pdisk
action=initialize controller=1 pdisk=4
Omconfig Offline Physical Disk
Description
Makes a physical disk offline.
Syntax
omconfig storage pdisk action=offline
controller=id pdisk=<PDISKID>, where id is
the controller ID. The <PDISKID> variable specifies the
physical disk.
NOTE: To obtain these values, type omreport storage
controller to display the controller IDs and then type
omreport storage pdisk controller=ID to display the
IDs for the physical disks attached to the controller.
Example to Offline physical disk 3 on connector 0 of controller 1. On a
SAS controller, the physical disk resides in enclosure 2.