Dell PowerEdge C6105 Cómo utilizar Pagina 62

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 68
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 61
62
77h Get PSU
Present Status
Request
Response:
Byte 1 - Completion code
Byte 2 - Present Status
[7] - 1b : PSU2 Present
[6] - 1b : PSU1 Present
[5] - 1b : PSU2 AC Present
[4] - 1b : PSU1 AC Present
[3] - Reserved
[2] - Reserved
[1] - Reserved
[0] - Reserved
78h Set System
Power
Capping
Request:
Byte 1 - Enable Power Capping
0x01 : Enable
0x00 : Disable
Byte 2- Power Capping Value
(LSB)
Byte 3- Power Capping Value
(MSB)
Response:
Byte 1 - Completion Code
79h Get System
Power
Capping
Request:
Response:
Byte 1 - Completion Code
Byte 2 - Power Capping Enable
Status
Byte 3:4 - Power Capping Value
Table 1-46. OEM Commands Group 3 (Net-function: 0 x 34)
(continued)
Net Function = OEM (0x30), LUN = 00
Code Command Request, Response Data Description
Vista de pagina 61
1 2 ... 57 58 59 60 61 62 63 64 65 66 67 68

Comentarios a estos manuales

Sin comentarios