Vista de pagina 65
66
DCMI V1.0
The following table lists the command support list.
VLAN Configuration
The VLAN is confiugred through the IPMI Set/Get LAN Configuration
command.
To configure the VLAN:
4
Get VLAN ID :
>ipmitool -H <BMC IP Address> -I lanplus -U root -P root raw 0x0C
0x02 0x01 0x14 0x00 0x00
>11 00 00
VLAN is disabled/VLAN ID is zero.
5
Enable and Set VLAN ID :
>ipmitool -H <BMC IP Address> -I lanplus -U root -P root raw 0x0C
0x01 0x01 0x14 0x02 0x80
6
Disable VLAN ID :
>ipmitool -H <BMC IP Address> -I lanplus -U root -P root raw 0x0C
0x01 0x01 0x14 0x00 0x00
BMC Version Information
The BMC firmware version can be obtained by using the IPMI - Get Device
ID command.
To get the BMC firmware version:
Table 1-47. DCMI Commands
Command NetFn CMD O/M Supported
Get DCMI Capability Info DCGRP (2Ch) 01h M Yes
Get Asset Tag DCGRP (2Ch) 06h M Yes
Get DCMI Sensor Info DCGRP (2Ch) 07h M Yes
Get Power Reading DCGRP (2Ch) 02h O Yes
Get Power Limit DCGRP (2Ch) 03H O Yes
Set Power Limit DCGRP (2Ch) 04h O Yes
Activate/Deactivate Power Limit DCGRP (2Ch) 05h O Yes