Dell Acceleration Appliances for Databases Manual de usuario Pagina 57

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 89
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 56
3. Restart multipathd as indicated on the first line.
# copy this file to /etc/multipath.conf and restart multipathd
defaults {
user_friendly_names yes
queue_without_daemon no
}
devices {
device {
vendor "FUSIONIO"
features "0"
hardware_handler "1 alua"
path_grouping_policy group_by_prio
path_selector "queue-length 0"
failback immediate
path_checker tur
prio alua
no_path_retry 3
# Uncomment if using FC. Do not use for SRP and iSCSI
#fast_io_fail_tmo 15
#dev_loss_tmo 60
}
}
Restarting Multipathing
If your multipath configuration changes, you may need to restart multipathing, as in this example:
# multipathd -k
multipathd> reconfigure
ok
multipathd> show config
multipathd> exit
When using the show config command, you will need to search through the output and make sure it
matches what was entered in
/etc/multipath.conf.
If the restart is not successful, you can try the following commands:
# multipath -F
# service multipathd stop
# service multipathd start
// confirm the new settings are used for existing multipath devices
# multipath ll
50