Dell PowerEdge RAID Controller 6i Manual de usuario Pagina 120

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 156
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 119
120 Troubleshooting
Physical Disk Related Issues
Table 7-4 describes physical disk-related problems you might encounter and the
suggested solutions.
Table 7-4. Physical Disk Issues
Problem Suggested Solution
One of the physical
disks in the disk array
is in the failed state.
Perform the following actions to resolve this problem:
Check the backplane for damage.
Check the SAS cables.
Reseat the physical disk.
Contact Dell Technical Support if the problem persists.
Cannot rebuild a fault
tolerant virtual disk.
NOTE: For more
information, see the
alert log for virtual
disks.
This could result from any of the following:
The replacement disk is too small or not compatible with
the virtual disk. Replace the failed disk with a compatible
good physical disk with sufficient capacity.
Fatal errors or data
corruption are
reported when
accessing virtual disks.
Contact Dell Technical Support.
Dell_PERC6.1_UG.book Page 120 Wednesday, April 15, 2009 4:18 PM