Figure 4. Dedicated SAN Solution in the High Availability Option
NOTE: The MD32x0i storage array has four iSCSI data ports on each controller. Do not configure ports 2 and 3 on
the same subnets as the FluidFS NAS system. They can be connected to the same switch for other clients, but
must be configured on different subnets.
NOTE: For more information on the details of cabling the NAS controller(s) and the MD system(s), see Cabling
Overview.
Dedicated SAN Solution In The Non-Redundant Option
The dedicated SAN solution in the non-redundant option isolates the SAN traffic from the client traffic, but without
redundant switches. All the client cables are connected to the client switch and the SAN/Internal network cables are
connected to the SAN switch.
CAUTION: In this configuration, the switches become a single point of failure.
NOTE: It is recommended that you separate the SAN and client subnets using virtual LANs.