16. Click Next.
The Internal interconnect network screen is displayed.
17. If blank, enter the IP addresses for the Controllers, Winbind, and Subnet Mask.
The NAS iSCSI network screen is displayed.
18. Enter the IP addresses for the following:
SAN Network A
SAN Network B
Subnet mask
For SAN Networks A and B, enter the first IP address and as you enter the SAN network IP addresses the IP Range
for Controllers get updated.
19. To modify the IP Range for Controllers, click Modify and modify the IP addresses manually.
20. From the Network MTU list, select the appropriate MTU.
NOTE: Although the tool allows 1500 MTU, 9000 MTU is required for the SAN network. If MTU 1500 is not
configured on the SAN, the NAS reports 15% packet loss.
21. Click Next.
The iSCSI Target Discovery screen is displayed.
22. In iSCSI Discovery Address for MD Array, enter one of the iSCSI port IP addresses of the PowerVault MD array for
the iSCSI target.
NOTE: The NX3610 supports two MD storage arrays. In version 01.01.02.016 of the NAS IDU, if a second array
is not attached to the NX3610 cluster, enter the IP address of the single storage array twice.
23. Click Next.
NOTE: It is highly recommended to copy the configuration details from the Configuration Summary screen and
paste it in a different file (.doc or .txt) for future reference.
The Configuration Summary screen displays all the configuration details for the selected NAS appliance.
24. Click Next.
The NAS IDU applies the cluster configuration to the selected NAS appliance. After the configuration is complete,
the Configuration Results screen is displayed. The NAS controller IQNs are displayed in the Configuration Results
screen.
NOTE: It is highly recommended to copy the NAS controller IQN details from the Configuration Results screen
and paste it in a different file (.doc or .txt) for future reference. You must match these NAS controller IQNs in
the MDSM.
25. Set up your MD storage array using MDSM.
For more information, see Setting Up Your MD Storage Solution.
26. Click Finish.
17