Problem
l Error message indicates a RAID controller problem.
l RAID controller performs incorrectly or not at all.
Action
1. Run the appropriate online diagnostic test. See "Using Server Administrator Diagnostics" in "Running the System Diagnostics."
2. Remove the bezel. See "Removing the Bezel."
3. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
4. Open the system. See "Opening the System."
5. Ensure that the controller card is firmly seated in its connector. See "Installing a RAID Controller Card" in "Installing System Options."
6. Ensure that the appropriate cables are firmly connected to their corresponding connectors on the controller card.
7. Close the system. See "Closing the System."
8. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.
If the problem persists, see the RAID documentation for more information on troubleshooting.
Troubleshooting Expansion Cards
Problem
l Error message indicates a problem with an expansion card.
l Expansion card performs incorrectly or not at all.
Action
1. Run the appropriate online diagnostic test. See "Using Server Administrator Diagnostics" in "Running System Diagnostics."
2. Open or remove the bezel. See "Removing the Bezel."
3. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
4. Open the system. See "Opening the System."
5. Ensure that each expansion card is firmly seated in its connector. See "Installing an Expansion CardCard" in "Installing System Options."
6. Close the system. See "Closing the System."
7. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.
If the problem persists, go to the next step.